Installation manual

Express
®
Lavatory System - MG-Series with TouchTime
®
Control
Installation MG-2/TT
Bradley • 215-1480 Rev. G; ECN 13-08-025 4/9/2014 5
Installation Instructions
Step 1: Rough in supplies and optional hot water heater
NOTE: See Figure 1 (below), 1a, 1b (for TAS on page 6) and Figure 2 (on page 7) when roughing
in the MG-2/TT Express
®
.
IMPORTANT: Flush the supply lines before making connections. Debris in supply lines will cause
the valves to malfunction.
IMPORTANT: Dimensions shown in Figure 1 are for Standard Height Mounted
MG-2/TT Express
®
.
1. Rough in ½" nominal copper tubing for hot and cold supply lines through wall at dimensions shown.
2. Rough in 1½" NPT drain waste connection through wall at dimensions shown.
3. OPTIONAL HOT WATER HEATER: Rough in appropriate electrical supply per local code (recommended
240/208-volt or 277-volt electrical box location shown below).
4"
(102)
5"
(127)
FLOOR
14"
(356)
14"
(356)
*22³⁄₈"
(568)
*28¼"
(718)
*25¾"
(654)
½" NOMINAL COPPER TUBING
FOR HOT AND COLD SUPPLIES OR
TEMPERED SUPPLY – STUB OUT 2"
³⁄₈" WALL ANCHORS (8) PLACES MIN. PULL-OUT
STRENGTH 1000 LBS. PER ANCHOR
110V GFI
PROTECTED
ELECTRICAL
OUTLET
*Juvenile Height Mounting:
Subtract 4" from vertical dimensions for compliance with ADA guidelines for children’s use.
Figure 1
Standard Height Mounting
CENTERLINE
OF FIXTURE
" NPT DRAIN
STUB OUT 2"
*24½"
(654)
*26"
(660)
*31½"
(800)
" (95)
*19½"
(495)
4"
(102)
4" (102)
RECOMMENDED 240V/208V
OR 277V FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(2½" l x 3" w x 4" h)
RECOMMENDED
240V/208V OR 277V
FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(4" l x 3" w x 4" h)
*23"
(584)
H
C
16½"
(419)
APPROX. DIMENSION
25½" (648)
APPROX. DIMENSION
25½" (648)
A
A
B
B
B
B
B
B