Installation manual
Express
®
Lavatory System - MG-Series with TouchTime
®
Control
MG-2/TT Installation
16 4/9/2014 Bradley • 215-1480 Rev. G; ECN 13-08-025
Assembly of Components continued . . .
Sensor assembly and solenoid valve access
• Toaccesssolenoids:
Using a ⁵⁄₃₂" Allen socket wrench, loosen, but do not remove the three bottom access panel screws. Remove
the two top access panel screws and washers securing the panel to the frame and remove the access panel
(see Figure 3 on page 8). Solenoids are located on left side of frame (see Figure 10).
• To remove sprayhead:
Remove (3) bolts located underside of bowl neck (see Figures 9 and 11). Carefully remove sprayhead from
bowl.
• To access sprayhead/aerator/lens and sensor assembly:
Remove (2) screws and washers from the access plate assembly using a ¹⁄₈" Allen socket wrench. The access
plate assembly is located underneath the sprayhead (2) places (see Figure 12 on page 17), the assembly will
drop down to access the lens, sensor, and sensor eyes, housing flow control and tube connector.
Figure 10
Figure 11
SPRAYHEAD BODY
MOUNTING LOCATION
TO BOWL (3) PLACES
SPRAYHEAD AERATOR
ASSEMBLY S05-166
NAVIGATOR
MIXING VALVE
FRAME
SOLENOIDS
⁵⁄₁₆" I.D. BRAIDED
HOSE 269-1365