Installation manual

Express
®
Crescent
®
Lavatory System CRS-Series
CRS-2/IR, CRS-3/IR Installation
8 11-15-2011 Bradley Corporation • 215-1330 Rev. M; ECN 11-08-011
Installation Instructions continued . . .
Step 9: Adjust the Temperature
NOTE: This valve is NOT factory preset. Upon installation, the
temperature of this valve must be checked and adjusted to
ensure delivery of a safe water temperature. Water in excess of
110°F (43°C) may cause scalding.
1. Loosen the cap screw about ¼" (4–6 turns) and lift up the
cover (do not remove).
2. Using the cover, turn the cartridge gently until desired
water temperature is reached. Do not turn past stops
as this may damage the unit. Push the cover down and
tighten the screw.
3. After testing is complete, reinstall panel to frame.
Installation Instructions continued . . .
Figure 6b
Green Spade
Terminal
Black Supply Tube
(From Sprayhead)
Red Spade
Terminal
White Spade
Terminals
Red Supply Tube
(From Sprayhead)
Black Spade
Terminal
Transformer Circuit
Plug
Navigator
®
Thermostatic
Mixing Valve
Compression Nut
(110-231)
Green Supply Tube
(From Sprayhead)
Sensor Circuit Plug
Supply Inlet
H
C
Figure 7