Installation manual

Express
®
Crescent
®
Lavatory System CRS-Series
CRS-2/IR, CRS-3/IR Installation
4 11-15-2011 Bradley Corporation • 215-1330 Rev. M; ECN 11-08-011
* ADJUSTMENTS TO VERTICAL DIMENSIONS FOR VARIOUS RIM HEIGHTS
Rim Height Application Adjustment
34” Adult Height ADA, TAS Adult Height TAS Adult Height None, as shown
32” TAS Ages 11 thru 14 or 15, Grades 6 thru 8 or 9 Subtract 2”
30” TAS Ages 4 thru 10 or 11, Grades: Pre-K thru 5 or 6 Subtract 4”
& Proposed Juvenile Height ADA
24” Preschool (required by some local codes) Subtract 10”
Installation Instructions continued . . .
Step 1: Rough-ins cont’d.
2. Install a 110 volt GFI protected electrical outlet per local code at the location shown in Figure 2.
3. Install six
3
/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the
locations marked in Figure 2.
4. OPTIONAL TRAP COVER: Install one ¼ wall anchor at the location marked in Figure 2.
Figure 2
Standard Height Mounting
3
8" Wall Anchors (6) Places, Min. Pull-Out
Force 1,000 lbs. Per Anchor.
(mm)
10"
(254)
7
11
16"
(195)
10"
(254)
10"
(254)
10"
(254)
13½"
(343)
13½"
(343)
33½"
(851)
31"
(788)
22¾"
(578)*
3¾"
(45)
(4) ¼" Wall
Anchors for
Optional
Soap System
Optional ¼" Wall
Anchor For Trap
Cover (Use Trap
Cover For Template)
Floor
C
L
10½"
(267)
110 Volt GFCI Protected
Electrical Outlet (Recommended
Location) (Check Local Electrical
Codes Before Roughing In)
27¼"
(692)
35"
(889)*