Installation manual

Aerada 1000/1100 Series Installation
12 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201
CARE AND MAINTENANCE INSTRUCTIONS
The following instructions are described in this section:
• Activating Cleaning Mode
Replacing Battery
Cleaning or Replacing Inlet Filter
Adjusting Water Temperature (Internal Mixer)
Adjusting Hot Water Limiter (External Mixer)
Cleaning or Replacing Aerator
Activating Cleaning Mode
In order to set the cleaning mode, the faucet needs to be have been set once into
the “Manual Setting” mode. See “Manual Setting” instructions. When cleaning
mode is activated, the faucet will be inoperable for 90 seconds.
1 Fully cover sensor with hand, until water fl ow stops. (This takes approximately
5 seconds.)
2 Remove hand.
Result: Cleaning Mode is now activated.
Replacing Battery
A traditional lavatory faucet is shown as an example. These instructions apply to
all DC models.
Prerequisites
• Battery is low (LED is lit)
New 6 V Lithium battery (CR-P2) is required
1 Remove shut-off screw
2 Remove mixer handle (for faucets with external mixer only)
3 Remove housing vertically.
4 Remove used battery from battery holder and recycle.
5 Insert new battery.
> LED lights up for 1 second
6 Mount housing vertically.