Service Manual

66
Service Procedure I:
Thermostat Circuit Testing and Replacement (Continued)
Thermostat Sensor (Thermistor)
Replacement Procedure
1. Position main power switch to OFF.
2. Disconnect (unplug) water heater from 120 volt power source.
3. Unlatch and remove the top surround cover from the top of the water heater.
4. Unclip sensor connector from the control board and remove the harness from the control panel (see
below images).
5. Unclip sensor from the well and pull the sensor to remove, do NOT remove well.
6. Install new sensor assembly into well and reinstall the sensor clip.
7. Reconnect the sensor connector to the control board and route the wire harness through the same
path that it was removed.
8. Restore 120 volt power supply and water supply to the water heater, check and repair any leaks
found. Confirm proper operation following the lighting instruction label or the lighting instructions
located in the Installation and Operating Instruction Manual.
9. Replace the surround cover on the top of the water heater.
Remove sensor
connector from
control board
Sensor shown fully
inserted into well
Sensor clip shown
properly installed
WARNING
120 volt potential exposure. Use caution
making voltage checks to avoid personal injury.
66