Service Manual

65
Service Procedure I:
Thermostat Circuit Testing and Replacement (Continued)
Condition: Water heater not operating.
Display shows error code 65, high water
temperature (over 200°F).
Continued from previous page.
Once cause of overheating condition has been
diagnosed and corrected, the control may be reset.
Reconnect and switch ON power to the water heater.
Enter Service Mode on the water heater display (see image).
Press button under “Lockout Reset” and hold for 3 seconds.
Set thermostat to the desired setting. Water heater will start.
Monitor temperatures for one complete heating cycle, making
sure the maximum tank temperature remains well below 200°F.
WARNING
DO NOT operate the water heater without verifying
that the overheating condition has been corrected.
65