Spec Sheet

Commander Series
®
Atmospheric Vent Commercial Gas Water Heater
NATURAL AND LIQUID PROPANE GAS
Commander Series
®
Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
K
Floor to
Cold
Water
Conn.
in.
Approx.
Shipping
Weight
lbs.
E
Floor
to
Gas
Conn.
in.
A
Floor
to
Flue
Conn.
in.
Input
BTU/Hr.
Nominal
Gal.
Capacity
U.S.
Gal.
L
Floor
to Hot
Water
Conn.
in.
C
Vent
Size
in.
140°F100°F40°F
GPH Recovery
at Degree Rise*
UCG-80H-125-3N(A)
UCG-80H-199-3N(A)
UCG-80H-270-3N(A)
UCG-80H-399-3N(A)
UCG-100H-199-3N(A)
UCG-100H-270-3N(A)
UCG-100H-399-3N(A)
125,000
199,999
270,000
399,999
199,999
270,000
399,999
308
493
665
960
493
665
994
123
197
266
384
197
266
398
88
141
190
274
141
190
284
80
80
80
80
100
100
98
Imp.
Gal.
67
67
67
67
83
83
82
63
3
/8
63
3
/8
63
3
/8
63
3
/8
73
1
/4
73
1
/4
77
7
/16
5
6
6
8
6
6
8
9
3
/16
9
3
/16
9
3
/16
9
3
/16
9
13
/16
9
13
/16
9
13
/16
3
/4
3
/4
1
1
3
/4
1
1
46
15
/16
46
15
/16
46
15
/16
46
15
/16
53
7
/8
53
7
/8
53
7
/8
54
3
/8
54
3
/8
54
3
/8
54
3
/8
62
7
/8
62
7
/8
62
7
/8
28
28
28
28
28
28
28
32
32
32
32
29
5
/8
29
5
/8
29
5
/8
43
15
/16
43
15
/16
43
15
/16
43
15
/16
52
3
/8
52
3
/8
52
3
/8
52
3
/16
52
3
/16
52
3
/16
52
3
/16
60
11
/16
60
11
/16
60
11
/16
D
Floor
to
T&P
Conn.
in.
F
Floor
to
Top of
Heater
in.
Relief
Valve
Open
in.
Model
Number
K
Floor to
Cold
Water
Conn.
mm.
Approx.
Shipping
Weight
kgs.
E
Floor
to
Gas
Conn.
mm.
A
Floor
to
Flue
Conn.
mm.
Input
kW
Nominal
Liter
Capacity
L
Floor
to Hot
Water
Conn.
mm.
C
Vent
Size
mm.
78°C56°C22°C
LPH Recovery
at Degree Rise*
UCG-80H-125-3N(A)
UCG-80H-199-3N(A)
UCG-80H-270-3N(A)
UCG-80H-399-3N(A)
UCG-100H-199-3N(A)
UCG-100H-270-3N(A)
UCG-100H-399-3N(A)
36.6
58.6
79.1
117.2
58.6
79.1
117.2
1164
1864
2517
3634
1866
2517
3757
466
746
1007
1454
745
1006
1476
333
533
719
1038
533
719
1060
303
303
303
303
379
379
371
1610
1610
1610
1610
1835
1835
1967
127
152
152
203
152
152
203
233
233
233
233
249
249
249
19
19
25
25
19
25
25
1192
1192
1192
1192
1368
1368
1368
G
Floor to
Cold Water
Conn./Hot
Water Conn.
in.
54
3
/4
54
3
/4
54
3
/4
54
3
/4
63
1
/4
63
1
/4
63
1
/4
G
Floor to
Cold Water
Conn./Hot
Water Conn.
mm.
1391
1391
1391
1391
1607
1607
1607
1381
1381
1381
1381
1597
1597
1597
H
Depth
in.
H
Depth
mm.
813
813
813
813
752
752
752
B
Jacket
Dia.
in.
B
Jacket
Dia.
mm.
711
711
711
711
711
711
711
535
535
545
545
632
632
657
243
243
247
247
286
286
298
1116
1116
1116
1116
1330
1330
1330
1326
1326
1326
1326
1541
1541
1541
D
Floor
to
T&P
Conn.
mm.
F
Floor
to
Top of
Heater
mm.
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2
S
Gas
Conn.
Size
in.
13
13
13
13
13
13
13
S
Gas
Conn.
Size
mm.
1
1
/2
1
1
/2
1
1
/2
1
1
/2
1
1
/2
1
1
/2
1
1
/2
M
Water
Conn.
NPT
in.
38
38
38
38
38
38
38
M
Water
Conn.
NPT
mm.
Relief
Valve
Open
mm.
Up to 82% Thermal Efficiency
For Propane Gas models change suffix “N” to “X”. Example: UCG-100H-199-3X (UCG-100H-399 available in Natural Gas only). All models comply with the
latest Ultra Low NOx requirements (14 ng/J or less for natural gas and 77 ppm NOx limit for liquid propane).
Amp Draw range = 1.0 to 1.8 amps.
(A) ASME - All models are available with ASME construction.
To order ASME construction add the (A) to the end of the model number.
* Based on manufacturer’s rated recovery efficiency.
B
H
E
K
M
M
M
L
A
M
S
C
D
F
G
Sample Specification
The water heater shall be a Bradford White model UCG-_____ with a rated storage capacity of not less than _____ gallons/ liters, a minimum gas input of __________ BTU/Hr., a minimum
recovery of _____ GPH/LPH at 100°F (56°C) temperature rise, a Thermal Efficiency Rating of _____. It shall be design certified by CSA International (formerly AGA and CGA) for 180°F (82°C)
application, either with or without a separate storage tank. The tank shall be lined with Vitraglas
®
vitreous enamel and shall have a bolted hand hole cleanout. This water heater shall be
equipped with stainless steel cold water inlet, Hydrojet
®
Sediment Reduction System. The heater shall be insulated with Non-CFC foam. This water heater shall be equipped with an ICON
HD
®
ignition system, an ASME rated T&P relief valve and a premix combustion system. The water heater shall be factory assembled and tested. A digital LCD display shall be integrated into
the front and be an adjustable electronic thermostat to any temperature up to 180°F. A recycling Energy Cut Off (E.C.O.) shuts off all gas in the event of an overheat condition. The entire
installation shall be made in compliance with state and local codes and ordinances.
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All models are design certified by CSA International (formerly AGA/CGA), to
ANSI standard Z-21.10.3, for up to 180°F (82°C) application as an Automatic Storage Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems.
It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it can supply 180°F (82°C) sanitizing and lower temperature general purpose
hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended).
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Model
Optional Air Intake Ducting Maximum Lengths
2"
PVC, ABS,
or CPVC
20 ft.
20 ft.
20 ft.
20 ft.
20 ft.
N/A
N/A
3"
PVC, ABS,
or CPVC
50 ft.
50 ft.
50 ft.
50 ft.
50 ft.
25 ft.
25 ft.
4"
PVC, ABS,
or CPVC
75 ft.
75 ft.
75 ft.
75 ft.
75 ft.
50 ft.
50 ft.
UCG-80H-125-3(N,X)
UCG-80H-199-3(N,X)
UCG-100H-199-3(N,X)
UCG-80H-270-3(N,X)
UCG-100H-270-3(N,X)
UCG-80H-399-3(N,X)
UCG-100H-399-3N
Optional Power Vent Kits – for side wall
termination only.
Model Numbers Kit Number
UCG-80H-125/199/270,
UCG-100H-199/270: 239-81764-00
UCG-80H-399,
UCG-100H-399: 239-81766-00
BACnet
®
Gateway Kit Number – 415-53943-00.
Optional Honeywell EnviraCOM
Alarm Module – Provides indication (contacts are closed) when an alarm is present via normally open
contacts (rated for up to 24 VAC). Kit Number – 265-51961-00.
TYPICAL APPLICATIONS
B
H
E
K
M
M
M
L
A
M
S
C
D
F
G
Vent Kit
©2021, Bradford White Corporation, USA. All rights reserved.
Printed in U.S.A.
Sales: 800-523-2931
n
Fax 215-641-1612
24/7 Technical Support: 800-334-3393
n
Email techserv
@
bradfordwhite.com
741-F-0221