Service Manual

Accessing Service Mode on Control Display
For models with Honeywell Integrated Control
To Display Flame Sense Current of the Pilot Flame Sensor:
The pilot flame sense current is available only when the burners are in operation. Step 1: Make sure the status displays
“Heating” or draw enough hot water to start the burners. Step
2: Enter the “Service Mode” described previously. Step 3:
Press the “Select” button until a number value is displayed with Flame Current” to the right of the number. The value
displayed is in microamps (A).
SELECTSET
Status
Operational
Flame
Current
Heating
A
To Display and Change Temperature Setpoint:
Step 1: In “Service Mode” press the “Select” button until “Setpoint” is shown in the water heater
display
SELECTSET
Status
°F
idle
setpoint
Operational
18
18