ICON - Ultra Low NOx Water Heaters
ERROR CODE DEFINITION SERVICE ACTION POSSIBLE PARTS NEEDED
No LED No pilot light / Heater not in operation Follow lighting instructions 1) None
on the water heater
One flash & three second pause Knob in pilot position or thermostat satisfied None 1) None
LED on continuously Control knob turned to the off position Wait for LED to go off before relighting 1) None
Two flashes & three second pause Weak pilot signal detected Verify pilot is lit 1) Pilot assembly
Check thermopile voltage output 2) Gas valve
Check wire connections at gas valve
Three flashes & three second pause Control has not seen temp rise Check temp probe ohms 1) Gas valve
in proper amount of time Check gas pressure
Verify water is not flowing
Four flashes High tank temperature Check temp probe ohms 1) Thermowell
& three second pause Check gas valve 2) Gas valve
Five flashes & three second pause Thermostat sensor fault Check temp probe ohms 1)Thermowell
Check gas valve cover 2) Gas valve
Six flashes & three second pause Chamber door temp sensor out of specification Check door sensor ohms 1) Chamber door sensor
Clean screenlok
Clean burner
Seven flashes Gas valve fault Reset gas valve; if problem persists 1) Gas valve
& three second pause replace gas valve
Eight flashes Pilot remains lit while the control knob Check gas pressure 1) Gas valve
& three second pause is in off position Replace gas valve
Ten flashes & three second pause Insufficient combustion air detected Check gas pressure 1) Chamber door sensor
Clean screenlok
Check venting
Clean burner
NOTE:
Check all wire connections
Check gas inlet and manifold gas pressure
Check for grounding connections
Technical Support
800-334-3393