Service Manual
U TTW SERVICE PROCEDURE XII
Dip Tube
Inspection and replacement
Step1. Position gas control power switch to the “OFF”
position and unplug water heater from wall outlet.
Step 2. Turn off cold watersupply towater heater. Connect hose todrain valve of water heater and route to an
opendrain. Open a nearby hot water faucettovent heater for draining. Opendrain valve of water
heater and allow heatertodrain to a point below the inlet connection nipple.
Step3. Disconnect inle
t nipple from plumbing system.
Step4 With an appropriate tool such as a pipe wrench, remove inlet nipple/dip tube from the water heater.
Use caution nottodamage pipe threads.
Step5. Vi
sually inspect inlet nipple/dip tube. Inlet nipple/dip tube should be free of cracks and any blockage.
Hydro-jetslots should be open and free of any blockage.
Any damage such as cracks, restriction due todeformat
ion or unintentionalholes are not field
repairableand the inlet nipple/dip tube must be replaced.
Step6. Upon completion of inspection orsubsequentreplacement, reinstall inlet nipple/dip tube in
towater
heater. Connect nipple to plumbing system, resume watersupply and refill withwater.
Step7. To resume operation follow the instructions locatedonthe lighting instruction labelorthe lighting
instruc
tions locatedinthe installation and operation manual.
Dip Tube Inspection and Replacement
WARNING
Water Heater components and stored water maybe HOT when performing the following
steps in this procedure. Take necessary precaution to prevent personal injury.
Page 33
Gas Control shown in the “OFF” Position
R
33