Service Manual

Resettable Thermal Switch Replacement
Step1. Position gas control powerswitch to
the “OFF” position.
Step 2.Remove outer jacket door.
Step3. Disconnectredwire leads from resettable thermal switch.
Step4. Remove (2) ¼” hex drive screws from the manifold
cover and slid t
o the rightto remove from burner
assembly.
Step6. Remove resettable thermal switch from manifold
cover (Phillipsscrewdriver).
Step7. Place new resettable thermal switch in place.Be
sure contactsurface of resettable thermal switch and
manifold cover are free of any debris.Secure resettable thermal switch intoplace using screws from step6.
DO NO
T OVERTIGHTEN SCREWS.
Step8. Place manifold cover back in position and secure using the screws from step4.
Step9. Reconnect wire leads from gas control and thermopile to resettable th
ermal switch.
Note: Wire termination is interchangeable with eitherresettable thermal switch connection.
Step 10. Replace outer jacket door.
Step 11. To resume oper
ation follow the instructions locatedonthe lighting instructions labelorthe lighting
instructions locatedinthe installation and operation manual.
Manifold Cover
¼” Hex Drive Manifold
Cover Screws
Phillips Screws
Red Wire Leads
UTTW SERVICE PROCEDURE IX
Resettable Thermal Switch Testing
and Replacement
Page 30
Gas Control shown in the “OFF” Position
R