Installation / Operation Instruction Manual

61
Troubleshooting
RTG-L-199/160N/X1 – 6 721 827 274 (2022/06)
After installation, the appliance shows repeated
unresolved errors ( chapter 9).
In Natural Gas installations where energy content is less
than 900 BTU/cu ft.
After replacement of electronic control unit, fan or gas
valve.
Improper gas pressure will affect combustion.
Please see chapter 4.14 for more information.
8.11.1 Automatic adjust of Gas/Air flow
Press and hold simultaneously buttons , and
for 3 seconds.
Press the buttons or to select UC (Combustion
Automatic Adjustment) menu.
Press the button to enter UC menu.
Automatic adjustment will begin.
Open hot water taps when the display shows Tap Symbol
image (1 tub and 2 sinks should be sufficient; when there is
enough water flow the image disappears).
Fig. 57 Combustion Auto Adjust - Open Taps
The Combustion Auto Adjust process takes several minutes.
Steps from 1 to 7 will appear on the display.
Do not interfere with the appliance during the auto
adjustment process.
If the display shows “AD” during calibration process,
Press button which will resume the calibration process
Wait until display shows DN blinking as a sign of calibration
complete.
Touch the symbol to exit UC menu.
Gas and Air auto adjustment is complete.
In case of failure in the auto calibration process the error sign
appears.
Verify if:
Any error codes appear on the display. See table 30.
Gas type and pressure are correct.
Wind conditions are stable (e.g. wind gusts may be a cause
of failure).
Hot water flow is sufficient and stable (e.g. water from a
well is a potential source of water instability).
In case of positive results for all these actions:
Exit UC menu and repeat the process.
If failure persists:
Perform manual adjustment according to chapter 8.11.2
or contact Bradford White support line for further
assistance.
8.11.2 Manual adjust Gas/Air flow
Gas/Air flow adjustment is also possible to perform manually
(only recommended if automatic adjustment can not conclude
successfully).
First step - Adjust the maximum power (P1)
Press the button to turn ON.
Press and hold simultaneously buttons , and
for 3 seconds, until display reads P4.
Fig. 58
Press the buttons or to select P1 (Maximum
Power) menu.
Open hot water faucets when the display shows Tap
Symbol image (1 tub and 2 sinks should be sufficient;
when there is enough water flow the image disappears).
Press to enter P1 adjustment.
Display shows E.
Press or until L1 appears.
Press the button to enter L1.
Display shows L1 value.