Service Manual
Page 4
2.2 Available Accessories
Anti-Freeze Kit
Allows the protection of the appliance against water freezing inside of its pipes / heat exchanger.
The anti-freeze kit can be used where ambient temperatures are as low as -30°F/-35°C for short
periods of time.
Additional measures must be taken to the surrounding pipes connected to the unit in case it is
installed in a place where freezing temperatures are constant.
The heating elements in the Anti-Freeze kit are protected by ceramics and are clipped to the copper
pipes.
Figure 1 – Anti-Freeze Kit
The kit includes 16 resistances for the indoor version and 13 resistances for the outdoor version,
which activate under conditions from table 2. Each resistance has +/- 16W of expected dissipated
power.
Activation
Deactivation
T
box
≤ 5ºC / 41ºF
T
box
≥ 10ºC / 50ºF
Table 2 – Anti-freeze activation conditions
4