Service Manual

Page 14
P4 Information Menu: Displays informational data regarding the unit. This submenu can be useful for
diagnosing the appliance, as needed.
P7 Gas Type Menu: This menu allows selection of the gas type for the appliance. Improper gas type will
affect appliance performance and can lead to unsafe operating conditions. To change the gas type, press
the Up and Down buttons to the correct gas type. Press the P button to set the appliance to the specific
gas type. See the Manifold section for more information on gas type conversion.
P4 - Information
0d
Chamber NTC - Water Temperature at exit of heat
exchanger
1d
Inlet NTC - Current temperature of the temperature
sensor of the water inlet pipe
2d
Outlet NTC - Current temperature of the temperature
sensor of the water outlet pipe
3d
Flow - Total water flow through the unit. Includes flow
through both the main and bypass valves
4d
Barometric Pressure - Current barometric pressure at
installation location
5d
Fan Speed - Current fan speed (Hz.)
6d
Output Power - Current burner power %
7d
SS Hex NTC - Temperature sensor of the flue gases
between the Primary and Secondary Heat Exchanger
8d
Exhaust Gas NTC - Temperature sensor of the flue gases
at the exhaust
9d
Ambient NTC - Current temperature inside the cabinet.
Sensor is located near the fan.
10d
External Tank - Current temperature on the external tank
(if connected)
E
Exit - (Return to P4 menu)
1F
First most recent error code
2F
Second most recent error code
3F
Third most recent error code
4F
Fourth most recent error code
5F
Fifth most recent error code
6F
Sixth most recent error code
7F
Seventh most recent error code
8F
Eighth most recent error code
9F
Ninth most recent error code
10F
Tenth most recent error code
E
Exit - (Return to P4 menu)
OD - Operation Data
FH - Failure History
P4
OD
FH
P7 - Gas Type
nA Natural Gas (NG)
LP Liquid Petroleum Gas (LPG)
P7