Service Manual
Page 53
The P2 mode can be accessed in the service mode, depending on adjustment and/or confirmation
need.
Minimum Power
adjustment
(Minimum gas and water flow)
Technician Level Comments
Minimum power burner
adjustment after repairs /
maintenance / gas
conversions
P2 contains the fan speed setting
(A2) and gas power (L2) at
maximum power
(depends on gas type / model)
(depends on gas type / model)
When P2 is visible, press “P” and enter in the 2
nd
level accessing
“E” for enter and/or exit P1
Adjustment of air flow
without change gas
conditions
Range from 0 to 40
Spare part default setting is 20
Adjustment of gas flow
without change air
conditions
Range from 0 to 40
Spare part default setting is 20
Table 19 – P2 Sub-Menus
Remote control registration
Comments
Not used
Table 20 – P3
53