Problem solving
RTG-K-199/160N/X2 – 6 720 813 642 (2022/06)
E4 Air temperature inside cabinet above 176 °F
(80 °C) or 2 minutes above 158 °F (70 °C).
Appliance burner cut off to prevent overheating.
▶ Check for flue gas leakage inside the cabinet
1)
▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Check sensor resistance [18] (section 11) and
replace the sensor if it is not according to
specification.
1)
2)
E5 Condensing unit flue gas temperature above
428 °F (220 °C) or 2 minutes above 392 °F
(200 °C).
Appliance burner cut off to prevent overheating.
▶ Descale appliance ( section 7.3).
1)
▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Check sensor resistance [16] (section 11) and
replace the sensor if it is not according to
specification.
1)
2)
E7 Electronic control unit internal error. ▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Replace electronic control unit.
1)
E8 Error during ionization test. Electronic control unit
internal error.
▶ Replace electronic control unit.
1)
E9 Thermal fuse [13] broken. ▶ Replace thermal fuse.
1)
EA
3)
Ignition failure. ▶ Check gas inlet pressure ( section 4.17).
1)
▶ Perform gas and air tuning ( section 8.11).
1)
EB Electronic control unit internal error. ▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Replace electronic control unit.
1)
EC Flame lost during operation. ▶ Check gas inlet pressure ( section 4.17).
1)
▶ Perform gas and air tuning ( section 8.11).
1)
EE Gas valve modulation solenoid [7] disconnected. ▶ Check gas valve wire connection.
1)
If the problem persists:
▶ Replace the gas valve and/or wire connections
and/or electronic control unit. For gas valve
replacement perform gas and air tuning (
section 8.11).
1)
EF Wrong gas connected (LP instead of NG) for
current appliance configuration.
▶ Check gas type ( section 3.3).
1)
F2
F3
F7
F8
Electronic control unit internal error. ▶ Reset error (press and hold on/off button for 3
seconds).
If appliance’s configuration is required:
▶ See section 6.5 to configure appliance (region,
power, type and gas type) and perform an
automatic combustion adjustment according to
the section 8.12.
▶ Replace electronic control unit.
1)
Display Description Solution