Installation / Operation Instruction Manual

39
Operating Instructions
RTG-K-199/160N/X2 – 6 720 813 642 (2022/06)
6.7.1 Gas conversion from NG to LPG
DANGER:
Fatal accidents!
Before any service or testing in the appliance,
Turn off the appliance.
Disconnect the power supply cord.
Shut off the gas supply.
The gas type conversion must only be carried out by a qualified
contractor.
Turn Off the appliance.
Remove the front cover from the appliance ( section
3.3.2).
Remove the four screws that retain the cover plate to the
gas manifold, see fig. 37 (plate in grey color).
Fig. 37 Gas manifold
Remove metal plate and seal.
The 3 restrictor plates should be pre-assembled onto their
tray, but if loose in box, follow installation instruction, as
shown in fig. 38 [1].
Insert the LP conversion plate in the appropriate location
shown in Fig. 38 [2].
CAUTION:
All three flow restrictors and seal must be assembled
according to the Fig. 38, to assure correct appliance
performance.
Fig. 38 199kBTU appliance gas conversion kit
Fig. 39 160kBTU appliance gas conversion kit
▶Tighten the four screws.
Open the gas supply valve.
Turn On the appliance.
Check for gas leak (e.g. use leak detector fluid, like water
and soap, over and around the metal plate) and act
accordingly.