Spec Sheet

©2021, Bradford White Corporation, USA. All rights reserved.
Customer Service / Sales: 1-866-690-0961 / 905-203-0600
24/7 Technical Support: 800-334-3393
n
Email techserv@bradfordwhite.com
NATURAL GAS AND LIQUID PROPANE GAS
Infiniti
®
K Series Indoor Models
Model
Number
GPM Flow Rate
at °F
Temperature Rise
RTG-K-160-N1
RTG-K-199-N1
Nat.
9,000 - 160,000
9,000 - 199,000
45°F
7.0
8.7
Uniform
Energy
Factor
Nat. and LP75°F
4.2
5.2
90°F
3.5
4.4
0.92
0.96
LP in.
17,000 - 160,000
17,000 - 199,000
Minimum
Water Flow
GPM
0.45
0.45
Maximum
Temperature
Setting
140°F
140°F
Approx.
Shipping
Weight
lbs.
73
79
Vent Conn.
2
2
Model
Number
LPM Flow Rate
at °C
Temperature Rise
RTG-K-160-N1
RTG-K-199-N1
Nat.
2.6 - 46.64
2.6 - 58.3
25°C
26.7
32.9
Uniform
Energy
Factor
Nat. and LP41.7°C
15.9
19.6
50°C
13.2
16.6
0.92
0.96
LP mm.
5.0 - 46.64
5.0 - 58.3
Minimum
Water Flow
LPM
1.7
1.7
Maximum
Temperature
Setting
60°C
60°C
Approx.
Shipping
Weight
kg.
33
36
Vent Conn.
51
51
Input (BTU/Hr.)
Input (kW)
General
* Where local codes permit. All potable water connections are 3/4" (19mm) NPT. Gas connections are 3/4" (19mm). Bradford White recommends consulting
the Installation and Operations Manual (IOM) for proper gas line sizing based upon the installation specifics.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable side of this system. The potable side may NEVER be
connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
Propane (LP) Models are not available for order from
the factory. All Natural Gas products shipped can be
converted to Propane (LP) without the purchase of
an additional kit.
Requires an electrical power supply from a 120VAC
60Hz., properly rated receptacle and must be
properly grounded. Power supply cord provided.
Printed in U.S.A.C1152-F-0721 CANADA
4
5
/16" (110)
SIDE VIEW
3
/4"
(19)
2
9
/16"
(65)
2
1
/2"
(64)
31
1
/2"
(800)
FRONT VIEW
6
3
/8"
(162)
6
3
/8"
(162)
5
13
/16"
(148)
18
19
/32" (472)
9
27
/32" (250)
6
11
/16"
(170)
3"
(76)
3
1
/2"
(89)
11
9
/16"
(294)
3
1
/2"
(89)
(mm)
TOP VIEW
(236)
9
9
/
32
"
(191)
7
1
/
2
"
BOTTOM VIEW
(133)
5
1
/
4
"
2" (51mm.)
Venting
Maximum
allowable
exhaust vent
length
Twin pipe
60 ft.
18m
Maximum
allowable
intake vent
length
60 ft.
18m
Combined
maximum
allowable
vent
120 ft.
37m
3" (76mm.)
Venting
Maximum
allowable
exhaust vent
length
Twin pipe
280 ft.
85m
Maximum
allowable
intake vent
length
280 ft.
85m
Combined
maximum
allowable
vent
560 ft.
171m
Exhaust
Descaling
Service
Port
Descaling
Service
Port
Gas Connection
Condensate
Drain
Power
Cord
Pressure
Relief
Valve
Connection
Hot Water
Outlet
Combustion
Air Supply
Cold Water
Inlet
Cold Water
Inlet Filter
Exhaust
Descaling
Service
Port
Descaling
Service
Port
Gas Connection
Condensate
Drain
Power
Cord
Pressure
Relief
Valve
Connection
Hot Water
Outlet
Combustion
Air Supply
Cold Water
Inlet
Cold Water
Inlet Filter
Infiniti
®
K Series Tankless Water Heater
Intelligent Cascading Kit: Any indoor Infiniti
®
K-Series tankless water heater purchased with the serial number “TEB0008188” and after, will have
cascading technology available. Up to 24 units can be connected together with ease. Part No. 7736502750 (One for each additional water heater).