Installation / Operation Instruction Manual
75
Protecting the environment
RTG-K-199/160N/X1 – 6 720 817 984 (2022/06)
14 Protecting the environment
Packing
The packing box may be fully recycled as confirmed by the
recycling symbol .
Components
Many parts in the heater can be fully recycled in the end of the
product life. Contact your city authorities for information about
the disposal of recyclable products.
Saving water resources:
▶ Make sure you close all the taps after any use. Avoid leaving
the taps dripping. Repair any leaking tap.
▶ Define the temperature you want, in the appliance. This
way you have the precise water flow needed (mixing cold
water to regulate temperature will increase the water flow
with consequent waste of water).
15 Installer Checklist to be completed by
installer upon installation
Installation manual should be left with the owner after the
installation is tested and completed.
Upon completion of the installation complete the checklist
below by answering YES or NO. If any of the answers below are
NO, the installation is not complete. Refer to the Installation
Manual section referenced below in order to complete the
installation.
Checklist to be completed by installer
Exhaust and combustion air Yes No Chapter
Vent and fresh air
terminations meet clearance
requirements
4.6.3
Vent and fresh air pipe's
equivalent length in
specification
Combustion air is from a clean
source (free from chemicals,
dust or other pollutants)
Water supply Yes No Chapter
Isolation valves installed on
water heater inlet and outlet
connections
4.10
Water lines flushed and inlet
filter cleaned
Cold water and hot water lines
are installed in correct
position. (Cold on right, hot on
left)
When the cold supply is turned
off no water come out of any
hot taps
Provided PRV installed with
proper pipe away to drain
4.9
Water pressure in range 3.2
Water quality requirements in
range
4.9
Condensate Yes No Chapter
Condensate drain line
installed with neutralizer