Service Manual
Page 31
Figure 24 – Inlet Water Valve Composed by a Motor Stepper (left) and a Flow Sensor (right)
In order to disassemble the water valve, it is necessary to remove the clips attaching the valve to the
water piping. Note that the motor stepper and the flow sensor are one only spare part. However, for
maintenance purposes it may be required to open the water valve.
4.10 Circulation Pump (L-Series only)
The circulation pump is responsible for recovering the home re-circulation loop to minimize wasted water
and increase user comfort.
Figure 24 – Circulation Pump
WARNING
Before performing any service, ensure the power is disconnected from the appliance.
31