Installation / Operation Instruction Manual

35
Operating Instructions
RTG-K-199/160N/X2 – 6 720 813 642 (2022/06)
Access to information / adjustments menu.
Display shows P4 (Information).
Press the button until the display shows P9 (Purge).
After 2 sec. the fan starts working to purge the exhaust
circuit.
The fan remains running until the Purge menu is exited, to do
so:
Press the button .
6.5.3 PC (Cascading)
Use this menu only after installing the cascading kit.
Only a qualified technician can change this parameter.
How to choose an option in PC (Cascading),
Press the button to enter PC (Cascading).
Press buttons or to scroll through the options.
MA (Primary)
Appliance define as Primary
SL (Secondary)
Appliance define as Secondary
OF (Off)
Turn off the cascading function
How to select an option,
Press buttons or to choose an option.
Press the button until selected option blinks.
Option is activated.
Press the button to exit PC menu.
6.5.4 SA (Settings)
Fig. 34 SA - Settings
This menu provide access to several parameters.
Access to information / adjustments menu.
Display shows P4 (Information).
Press the button until the display shows SA
(Settings).
Press the button .
Display shows E.
Press buttons or to choose the following
information.
E Exit
A0 Time
A1 Recirculation
A8 Startup Delay
A9 Units Set
Ab Region Selection
rS Recirculation Settings
Press the button to select the desired information.
A0 Time
How to set the time:
Press the button .
Menu Hours (12h or 24h) appears.
Press buttons or to insert values.
Long press on button to set values.
Value will blink and move to next menu.
Repeat this procedure for all the menus,
Hours (12h or 24h)
Minutes
AM or PM (Only if 12h is selected)
Week day (1- Monday, ..., 7- Sunday)
To define/change a value;
Use buttons or to change values.
Long press on button to set values.
To exit menus without setting values;
Short press on button .
A1 Recirculation
Choosing a recirculation program:
Press the button .