Installation / Operation Instruction Manual

29
Electrical connections
RTG-K-199/160N/X2 – 6 720 813 642 (2022/06)
4.17 Measuring gas pressure
4.17.1 Gas supply pressure
Confirm gas pressure upon installation.
Connecting manometer
Shut off gas supply at installer supplied shutoff valve for
this water heater.
Locate the inlet gas pressure test port (see Fig. 22).
Loosen the screw inside test port fitting (do not remove)
and connect the manometer tube to the test port (see
fig. 22).
Static Pressure Test
Turn the gas supply back on.
Record the static gas pressure reading in table 14.
Dynamic Pressure Test
Turn ON the appliance.
▶Access menu P1 Max. Power, see chapter 8.11.2.
Note: While in this mode the appliance will run constantly at
maximum power and allow maximum water flow.
For inlet gas pressure adjustment consider the following table:
Table 13 Minimum inlet gas pressure under full operation
Operate all other gas appliances (except heater) on the
same gas piping system at maximum output.
Open all hot water faucets to achieve a flow rate of at least
6 gallons per minute. (1 tub and 2 sinks should be
sufficient). If heater goes back to P2, open more hot water
fixtures to allow sufficient flow and access to P1.
Record the lowest operating gas pressure reading in
table 14.
Turn OFF the appliance.
Shut off gas supply.
Disconnect the manometer tube from the test point.
Tighten the screw inside test point fitting.
Gas pressures lower than 3.5" W.C. or 8" W.C. for LPG for
Natural Gas may result in reduced power output.
Fig. 22 Gas pressure test port
[1] Gas pressure measuring point
Table 14 Inlet gas pressure readings
5 Electrical connections
5.1 Electrical power supply
WARNING:
For safety reasons, disconnect the power supply cord to
the water heater before any service or testing is performed.
WARNING:
For safety reasons install a proper waterproof outlet.
DANGER:
This water heater must be electrically grounded in
accordance with the most recent edition of the National
Electrical Code. NFPA 70. In Canada, all electrical wiring to
the heater must be in accordance with local codes and the
Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on
the gas or water piping to ground the metal parts of the
heater.
Gas type NG LPG
Inlet gas pressure 3.5" WC 8" WC
Gas pressure Date
Static Gas Pressure Reading
Dynamic Gas Pressure
Reading
6720813642-14.2V
1