Installation / Operation Instruction Manual

18
Installation instructions
RTG-K-199/160N/X1 – 6 720 817 984 (2022/06)
Fig. 7 Distance between support boards
[1] Support boards
Vertical studs are typically 16" (406mm) on center.
Fig. 8 Leveling wall mounting bracket
Fig. 9 Mounting the heater
CAUTION:
Personal injury and property damage.
Appliance must be installed vertically.
4.6 Venting
DANGER:
Risk of CO poisoning!
Do not reduce the exhaust or combustion air vent pipe
sizes.
Do not common vent with any other vented appliance or
stove.
Do not use Type-B vent as the actual exhaust vent system
for the appliance.
DANGER:
Flue gas poisoning!
Failure to vent the exhaust gases to the outside (see table 5
for proper material) may result in dangerous flue gases
filling the structure in which it is installed.