Installation Manual

3
Introduction
6 720 811 758 (2014/05)
2 Introduction
Tools needed:
Phillips head screw driver
Small flat head screw driver
Needle-nosed pliers
3 Preparation
Push power button to "OFF" and unplug power cord.
Loosen two Phillips head screws on bottom rear of front
cover.
Pull cover bottom outwards then lift cover upwards to
remove.
4 Appliance identification
The high temperature activation is different for RTG 199ME
and RTG 199HE models. Here is how to identify which model
you have:
For RTG 199ME models see chapter 6, for RTG 199HE models
see chapter 7.
5 Control unit service position
Remove three Phillips screws on front of control unit
(Fig. 1).
Fig. 1 Control unit front
Turn control unit to expose the rear.
Remove rear hatch from control unit to expose circuit
board electrical connections. (Fig. 2).
Fig. 2 Control unit rear
Control unit rear (wiring not shown for clarity purposes).
Fig. 3 Control unit rear
Note: The installation of this high
temperature kit will reduce the heat
exchanger warranty to 5 years from the date
of original installation and operation. For
more details consult the water heater’s
installation manual for warranty period.
NOTICE: Damages to the PCB!
Avoid touching printed circuit board
(PCB) as static discharge may damage
circuitry.
DANGER: Risk of fatal injury from electric
shock!
Before servicing the water heater,
unplug power supply cord from outlet.
Failure to do so could result in severe
personal injury or death.
Type Model Number Model
Condensing 7 736 502 725 RTG 199HE
7 736 502 726 RTG 199HE
Table 2
Non-condensing 7 736 502 727 RTG 199ME
7 736 502 728 RTG 199ME
Type Model Number Model
Table 2
6720608920-09.1AL