Service Manual
Specifications
PV Series
9
Vent Tables
Venting Specifications for:
RG1PV55H
RG2PV75H
LG1PV55H
LG2PV75H
3" Diameter (7.6 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum Straight
Length ft. (m)
Minimum Straight
Length ft. (m)
Through the Wall
1
45 (13.7) 2 (.6)
Through the Wall
2
40 (12.2)
2 (.6)
Through the Wall
3
35 (10.7) 2 (.6)
Through the Wall
4
30 (9.1) 2 (.6)
Through the Roof
0
50 (15.2) 7 (2.1)
Through the Roof
1
45 (13.7)
7 (2.1)
Through the Roof
2
40 (12.2) 7 (2.1)
Through the Roof
3
35 (10.7) 7 (2.1)
4" Diameter (7.6 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum
Straight
Length ft. (m)
Minimum
Straight
Length ft. (m)
Through the Wall
1
175 (53.3) 10 (3.1)
Through the Wall
2
170 (51.8) 10 (3.1)
Through the Wall
3
165 (50.3) 10 (3.1)
Through the Wall
4
160 (48.8) 10 (3.1)
Through the Wall
5
155 (47.2) 10 (3.1)
Through the Roof
0
180 (54.9) 15 (4.6)
Through the Roof
1
175 (53.3) 15 (4.6)
Through the Roof
2
170 (51.8) 15 (4.6)
Through the Roof
3
165 (50.3) 15 (4.6)
Through the Roof
4
160 (48.8) 15 (4.6)
9