Service Manual
Specifications
PV Series
8
Vent Tables
Venting Specifications for:
RG2PV50H
LG2PV50H
3" Diameter (7.6 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum Straight
Length ft. (m)
Minimum Straight
Length ft. (m)
Through the Wall
1
55 (16.8) 2 (.6)
Through the Wall
2
50 (15.2)
2 (.6)
Through the Wall
3
45 (13.7) 2 (.6)
Through the Wall
4
40 (12.2) 2 (.6)
Through the Roof
0
60 (18.3) 7 (2.1)
Through the Roof
1
55 (16.8)
7 (2.1)
Through the Roof
2
50 (15.2) 7 (2.1)
Through the Roof
3
45 (13.7) 7 (2.1)
4" Diameter (10.2 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum Straight
Length ft. (m)
Minimum Straight
Length ft. (m)
Through the Wall
1
175 (53.3) 10 (3.1)
Through the Wall
2
170 (51.8) 10 (3.1)
Through the Wall
3
165 (50.3) 10 (3.1)
Through the Wall
4
160 (48.8) 10 (3.1)
Through the Wall
5
155 (47.2) 10 (3.1)
Through the Roof
0
180 (54.9) 15 (4.6)
Through the Roof
1
175 (53.3) 15 (4.6)
Through the Roof
2
170 (51.8) 15 (4.6)
Through the Roof
3
165 (50.3) 15 (4.6)
Through the Roof
4
160 (48.8) 15 (4.6)
8