Installation / Operation Instruction Manual
28
Thermostat Adjustment
The thermostat dial is adjusted to approximately 120°F (49°C) when shipped
from the factory. When adjusting the thermostat, it should be remembered that
lower temperature settings are more energy efficient. To adjust the thermostat,
turn the dial clockwise until the minimum acceptable temperature is set. It is
suggested that the starting point setting not exceed the 120°F (49°C) or “HOT”
setting on the thermostat.
Figure 7
NOTE: Taupe / Silver faceplate is approximately 160ºF (71ºC) maximum set
point; Dark (Battleship) Grey faceplate is approximately 180ºF (82ºC) maximum
set point.
Burner Flame Check
Steel Burner: These models are equipped with self-adjusting air mixture and
do not have an adjustable air shutter (see Figure 8, next page). At periodic
intervals a visual check of the main burner and pilot flames should be made to
determine if they are burning properly. The main burner flame should light
smoothly from the pilot.
DANGER
Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds
at a temperature setting of 140°F (60°C). To protect against hot water injury, install
an ASSE approved mixing valve in the water system. This valve will reduce point of
discharge water temperatures by mixing cold and hot water in branch water lines. A
licensed plumbing professional or local plumbing authority should be consulted.
Note: This water heater is equipped with an energy cut out device to prevent
overheating. Should overheating occur, turn OFF the electrical supply to the
water heater and contact a qualified service technician.
WARNING
DO NOT run out of propane gas. Damage to the water heater may occur.