Venting continued-
Venting System Condensation
Condensate formation does not occur in all installations of power vented water
heaters but should be protected against on installations where condensation
can form in the venting system.
Formation of condensation in the venting system of Power Vented water
heaters is dependent upon installation conditions including, but not limited to:
ambient temperature and humidity of installation location,
ambient temperature and humidity of venting space,
vent distance and slope,
and product usage.
NOTICE
For installations in Canada, field supplied vent piping must comply with CAN/CGA
B149.1 (latest edition) and be certified to the Standard For Type BH, Class II, 65°C,
Gas Venting Systems, ULC S636. Components of this listed system shall not be
interchanged with other vent systems or unlisted pipe/fittings. All components and
specified primers and cements of the certified vent system must be from a single
system manufacturer and not intermixed with other system manufacturer’s vent
system parts. The supplied vent connector and vent termination are certified under
ULC S636 and are also certified as part of the water heater. Refer to the following
tables for approved venting materials, primers, and cements. All approved primers
and cements are to be used within their marked time limitations.
Approved Venting Materials
For installations in the US only
PVC DWV Sch. 40 (ASTM D-2665)
PVC Sch. 40 (ASTM-D1785)
CPVC Sch. 40 (ASTM-F441, ASTM-
D2846)
PVC and CPVC (UL 1738, ULC S636)
ABS Sch. 40 DWV (ASTM D2661)
Polypropylene (UL 1738, ULC S636)
For installations in CANADA
ULC S636 approved PVC for flue gas
venting rated Class II, 65°C
ULC S636 approved CPVC for flue
gas venting rated Class II, 65°C
ULC S636 approved Polypropylene
for flue gas venting rated Class II,
65°C
Approved Primers and Cements
For installations in the US only
PVC and CPVC Primer (ASTM-F656)
PVC Cement (ASTM D-2564)
CPVC Cement (ASTM F493)
ABS Primer and Cement (ASTM D-2235)
For installations in CANADA
ULC S636 approved Primer and
Cement for flue gas venting rated
Class II, 65°C