Installation / Operation Instruction Manual

37
Troubleshooting continued-
LEDStatus ControlStatus ProbableCause
Sixflashestwo
flashes,threesecond
pause(Softlockout)
Pressureswitchor
blowertemperature
switchopened
duringburner
operation.
Systemautoresets
after5minutes.
1.Pressureswitchtubingkinkedorblocked.
2.Ventblockageorimpropervent
configuration.
3.Ventterminationbeingaffectedbywindy
conditions.
4.Blowernotspinning
uptospeed.
5.Venttemperaturetoohigh.
6.Faultypressureswitchorblowertemp.
switch.
Sixflashesthree
flashes,threesecond
pause(Softlockout)
Pilotflame
extinguished.
Systemresetsafter5
minutes.
1.Unstablepilot.
2.Pilottubeblockedorrestricted.
3.Oxidationbuilduponpilotelectrode.
4.Wiredamagetopilotassemblyorbad
connectionatgasvalve.
5.Insufficientcombustionair.
Sixflashesfour
flashes,threesecond
pause(Softlockout)
Undesiredfalsepilot
flamesensed.
Systemautoresets.
Pilotvalvestuckinopenposition.
Sevenflashes,three
secondpause
Flammablevapor
sensorfault
detected,see
warninglabel
1.Flammablevaporpresent
2.Flammablevaporsensorexposedto
excessive
moisture
3.Flammablevaporsensorexposedto
extreme
ambienttemp
Eightflashesone
flash,threesecond
pause
Flammablevapor
sensoroutof
specification.
Possibleshort.
1.Flammablevaporsensoroutof
specification
2.Possibleshort.
Eightflashes,two
flashes,threesecond
pause
Temperaturesensor
fault
1.Damagetosensororwireincontrol’swell.
2.Control’ssensorresistanceoutofrange.
3.Replacecontrol.
Eightflashesthree
flashes,threesecond
pause
Electronicsfault
detected
1.Verifycontrolisnotwetorphysically
damaged
2.Resetcontrolon/offswitch.
3.Replaceelectronicmoduleif83error
persists
Eightflashesfour
flashes,threesecond
pause
Gasvalvefault
detected.
1.Verifycontrolisnotwetorphysically
damaged.
2.Resetcontrolon/offswitch.
3.Replacegascontrolif84errorpersists