Service Manual
Specifications
PV Series
7
Vent Tables
Venting Specifications for:
RG1PV40S, RG2PV40T
RG1PV50S, RG2PV50T
2" Diameter (5.1 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum Straight
Length ft. (m)
Minimum Straight
Length ft. (m)
Through the Wall
1
45 (16.8) 2 (.6)
Through the Wall
2
40 (15.2)
2 (.6)
Through the Wall
3
35 (13.7) 2 (.6)
Through the Wall
4
30 (12.2) 2 (.6)
Through the Roof
0
50 (18.3) 7 (2.1)
Through the Roof
1
45 (16.8)
7 (2.1)
Through the Roof
2
40 (15.2) 7 (2.1)
Through the Roof
3
35 (10.7) 7 (2.1)
Through the Roof
4
30 (9.2) 7 (2.1)
3" Diameter (10.2 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum Straight
Length ft. (m)
Minimum Straight
Length ft. (m)
Through the Wall
1
115 (35) 10 (3.1)
Through the Wall
2
110 (33.5) 10 (3.1)
Through the Wall
3
105 (32.0) 10 (3.1)
Through the Wall
4
100 (30.5) 10 (3.1)
Through the Wall
5
95 (29.0) 10 (3.1)
Through the Roof
0
120 (36.6) 15 (4.6)
Through the Roof
1
115 (35) 15 (4.6)
Through the Roof
2
110 (33.5) 15 (4.6)
Through the Roof
3
105 (32.0) 15 (4.6)
Through the Roof
4
100 (30.5) 15 (4.6)
7