Installation / Operation Instruction Manual

13
CONNECTION TO 2 (5.1 CM)
VENT PIPE
CONNECTION TO 3 (7.6 CM)
VENT PIPE
Venting continued-
Figure 2
Through The Wall Venting (Horizontal Venting):
Cut a 2 1/2 in (6.4 cm) diameter hole in the wall at the point where the vent
connector is going to pass through the wall. Use the proper cement to secure
the 90° vent terminal provided with the water heater to the vent connector. The
distance between the edges of the 90° vent terminal and the exterior wall (see
Figure 3) must be at least 1 in (2.5 cm). Use the proper cement and assembly
procedures to secure the vent connector joints between the terminal and the
blower outlet. Provide support brackets for every 5 ft (1.5 m) of horizontal vent.
Figure 3
IMPORTANT
All of the venting connections must be leak checked with a soap and water
solution upon initial start-up of the water heater. Any leaks must be repaired
before continuing operation of the water heater.
3 VENT INSTALLATION
2 VENT INSTALLATION
3 VENT INSTALLATION
2” VENT INSTALLATION