Product Overview
©2016, Bradford White Corporation. All rights reserved.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
General: All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working
pressure. All water connections are 3⁄4" NPT (19mm), all gas connections are 1⁄2" (13mm). All models design-
certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and/ or 10.3 and peak performance rated.
Printed in U.S.A.1261-B-0716
Sales / Technical Support 866-690-0961 / 905-238-0100
l
Fax 905-238-0105 / www.bradfordwhite.com
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
l
Fax 215-641-1670 / Technical Support 800-334-3393
l
Fax 269-795-1089
l
Warranty 800-531-2111
l
Fax 269-795-1089
International: Telephone 215-641-9400
l
Telefax 215-641-9750 / www.bradfordwhite.com
Ambler, PA
Residential Power Vent Gas Water Heater
NATURAL GAS AND LIQUID PROPANE GAS
Power Vent Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Vent
Conn.
in.
K
Depth
in.
B
Jacket
Dia.
in.
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
57
5
/16
58
1
/4
57
5
/16
58
1
/4
66
7
/8
66
7
/8
66
1
/
8
64
3
/16
69
7
/16
27
7
/8
26
3
/4
26
3
/4
28
3
/4
24
1
/2
26
1
/2
26
3
/
4
26
1
/2
30
1
/4
20
22
22
24
20
22
22
22
26
2 or 3
2 or 3
2 or 3
2 or 3
2 or 3
2 or 3
3 or 4
3 or 4
3 or 4
49
50
1
/2
49
50
1
/2
58
58
57
3
/
4
56
60
3
/4
J
Floor to
Water
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Vent
Conn.
mm.
K
Depth
mm.
B
Jacket
Dia.
mm.
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
1456
1480
1456
1480
1699
1699
1680
1630
1764
708
679
679
730
622
673
679
673
768
64
76
508
559
559
610
508
559
559
559
660
51or76
51or76
51or76
51or76
51or76
51or76
76 or 102
76 or 102
76 or 102
C
Vent
Size
in.
C
Vent
Size
mm.
E
Floor to
Gas
Conn.
in.
11
3
/4
11
3
/4
11
3
/4
11
3
/4
11
3
/4
11
3
/4
11
3
/
4
11
1
/2
13
1
/2
E
Floor to
Gas
Conn.
mm.
298
298
298
298
298
298
298
279
343
F
Floor to
Top of
Heater
in.
47
1
/2
48
1
/4
47
1
/2
48
1
/4
56
3
/4
56
3
/4
56
3
/
8
54
5
/8
59
1
/2
F
Floor to
Top of
Heater
mm.
1207
1226
1207
1226
1441
1441
1432
1388
1511
H
C/L
of Water
Conn.
in.
8
8
8
8
8
8
11
8
11
H
C/L
of Water
Conn.
mm.
203
203
203
203
203
203
279
203
279
D
Floor to
T&P
Conn.
in.
40
40
5
/8
40
40
5
/8
50
50
50
1
/
8
47
15
/16
51
1
/2
D
Floor to
T&P
Conn.
mm.
1016
1032
1016
1032
1270
1270
1273
1218
1308
1245
1283
1245
1283
1473
1473
1467
1422
1543
J
Floor to
Water
Conn.
mm.
N/A
N/A
N/A
N/A
N/A
N/A
50
1
/
8
47
15
/16
51
1
/2
140
166
142
168
146
173
187
219
260
M
Floor to
Space Heating
Outlet
in.
N/A
N/A
N/A
N/A
N/A
N/A
1273
1218
1308
64
75
66
78
85
99
118
M
Floor to
Space Heating
Outlet
mm.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3
/
4
1
1
1
/4
N
NPT
in.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
19
25
32
N
NPT
mm.
N/A
N/A
N/A
N/A
N/A
N/A
13
1
/
2
13
3
/8
13
3
/8
L
Floor to
Space Heating
Inlet
in.
N/A
N/A
N/A
N/A
N/A
N/A
343
340
340
L
Floor to
Space Heating
Inlet
mm.
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
RG1PV40S6N
RG1PV50S6N
★ RG2PV40S6N
★ RG2PV50S6N
★ RG2PV40T6N
★ RG2PV50T6N
★ RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
40
50
40
50
40
50
48
55
75
33
42
33
42
33
42
42
46
62
40,000
40,000
40,000
40,000
40,000
40,000
65,000
78,000
76,000
38,000
38,000
38,000
38,000
40,000
40,000
58,000
78,000
75,500
43
43
43
43
43
43
70
84
82
36
36
36
36
36
36
58
70
68
41
41
41
41
43
43
62
84
81
34
34
34
34
36
36
52
70
67
151
189
151
189
151
189
182
208
284
11.7
11.7
11.7
11.7
11.7
11.7
19.1
22.9
22.3
11.1
11.1
11.1
11.1
11.7
11.7
17.0
22.9
22.1
72
86
72
84
72
86
112
N/A
N/A
0.66
0.65
0.67
0.67
0.70
0.70
0.70
N/A
N/A
273
326
273
326
273
326
424
N/A
N/A
0.66
0.65
0.67
0.67
0.70
0.70
0.70
N/A
N/A
155
155
155
155
163
163
235
317
307
163
163
163
163
163
163
265
318
310
Model
Number
Capacity Recovery at
90°F Rise*
U.S.
Gal.
Imp.
Gal.
Nat.
BTU/Hr.
Input
LP
BTU/Hr.
Input
Nat.
U.S.
GPH
Nat.
Imp.
GPH
LP
U.S.
GPH
LP
Imp.
GPH
Model
Number
Capacity Recovery at
50°C Rise*
Liters
Nat.
kW
Input
LP
kW
Input
1st Hour
Rating
(Gal.)
Energy
Factor
1st Hour
Rating
(Liters)
Energy
Factor
LP
Liters/
Hour
Nat.
Liters/
Hour
Propane models feature a Titanium Stainless Steel propane burner. For Propane
(LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6”
to “10” (Not available on RG1PV55H6N). *Based on manufacturer’s rated recovery
efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes.
Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
H = ENERGY STAR
®
Qualified.
2"
Vent Pipe
3"
Vent Pipe
RG2PV40S6N
RG2PV50S6N
RG1PV40S6N
RG1PV50S6N
RG2PV40T6N
RG2PV50T6N
†
50 ft.
7 ft.
45 ft.
40 ft.
35 ft.
†
120 ft.
15 ft.
115 ft.
110 ft.
105 ft.
Max. Equivalent Length
Min. Equivalent Length
Number 1
of 2
90° Elbows 3
3"
Vent Pipe
4"
Vent Pipe
RG2PV50H6N
RG1PV55H6N
RG2PV75H6N
†
50 ft.
7 ft.
45 ft.
40 ft.
35 ft.
†
180 ft.
15 ft.
175 ft.
170 ft.
165 ft.
Max. Equivalent Length
Min. Equivalent Length
Number 1
of 2
90° Elbows 3
Subtract 5ft. for each additional 90° elbow
†For high altitude installations, consult the installation instructions.
B
H
K
C
J
F
E
L
A
D&M
B
H
K
C
J
F
E
L
A
D&M