Product Overview
NATURAL GAS AND LIQUID PROPANE GAS
Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
78% Recovery Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Exhaust
Outlet
in.
K
Depth
in.
B
Jacket
Dia.
in.
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
59
11
/
16
60
7
/
8
69
72
30
1
/
2
32
1
/
2
30
5
/
8
36
156
186
205
392
22
24
22
26
50
13
/
16
51
13
/
16
60
63
3
/
4
J
Floor to
Water
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Exhaust
Outlet
mm.
K
Depth
mm.
B
Jacket
Dia.
mm.
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
1516
1546
1753
1829
775
826
778
914
71
84
93
178
559
610
559
660
C
Vent
Size
in.
2 or 3
2 or 3
3 or 4
3 or 4
C
Vent
Size
mm.
51 or 76
51 or 76
76 or 102
76 or 102
E
Floor to
Gas
Conn.
in.
14
14
13
5
/
8
16
1
/
4
E
Floor to
Gas
Conn.
mm.
356
356
346
413
F
Floor to
Top of
Heater
in.
49
1
/
2
50
1
/
2
58
3
/
4
62
3
/
4
F
Floor to
Top of
Heater
mm.
1257
1283
1492
1594
H
Floor to
Air
Intake
in.
59
3
/
8
60
3
/
8
67
70
3
/
8
H
Floor to
Air
Intake
mm.
1508
1534
1702
1788
D
Floor to
T&P
Conn.
in.
42
1
/
2
43
1
/
2
52
1
/
4
54
1
/
4
D
Floor to
T&P
Conn.
mm.
1080
1105
1327
1378
1291
1316
1524
1619
J
Floor to
Water
Conn.
mm.
—
—
15
3
/
4
19
L
Floor to
Space Heating
Return
in.
—
—
400
483
L
Floor to
Space Heating
Return
mm.
—
—
52
1
/
4
54
1
/
4
M
Floor to
Space Heating
Supply
in.
—
—
1327
1378
M
Floor to
Space Heating
Supply
mm.
Model
Number
Capacity Recovery at
90°F Rise*
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
U.S.
Gal.
40
50
48
75
Imp.
Gal.
33
42
40
62
Nat.
BTU/Hr.
Input
40,000
40,000
60,000
80,000
LP
BTU/Hr.
Input
38,000
38,000
60,000
78,000
Nat.
U.S.
GPH
43
43
65
86
Nat.
Imp.
GPH
36
36
54
72
LP
U.S.
GPH
41
41
65
84
LP
Imp.
GPH
34
34
54
70
Model
Number
Capacity Recovery at
50°C Rise*
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
Liters
151
189
182
284
Nat.
kW
Input
11.7
11.7
17.6
23.4
LP
kW
Input
11.1
11.1
17.6
22.9
1st Hour
Rating*
(Gal.)
72
86
100
—
Energy
Factor
0.70
0.70
0.68
—
1st Hour
Rating*
(Liters)
313
326
379
—
Energy
Factor
0.70
0.70
0.68
—
LP
Liters/
Hour
155
155
246
318
Nat.
Liters/
Hour
163
163
246
326
Power Direct Vent Gas Water Heater
General:
Meets NAECA Requirements (Applicable Models).
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT
(19mm). All gas connections are 1/2" (13mm).
All models design-certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".
For 10 year model, change suffix “6” to “10”.
*Based on manufacturer’s rated recovery efficiency.
110 VAC Required for Power Venting / 110 VAC, 60HZ, 3.1 Amperes.
Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
★ = ENERGY STAR
®
Qualified.
K
C
J
F
E
L
B
D & M
A
H
Subtract 5ft. for each additional
90º elbow.
2" Vent Pipe
RG2PDV40S6N
RG2PDV50S6N
35
ft.
35
ft.
7 ft.
30 ft.
25
ft.
20 ft.
1
2
3
1
2
3
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90° Elbows
3" Vent Pipe
RG2PDV40S6N
RG2PDV50S6N
RG2PDV50H6N
RG2PDV75H6N
85 ft.
85 ft.
7 ft.
80 ft.
75 ft.
70 ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90° Elbows
60 ft.
60 ft.
7 ft.
55 ft.
5
0 ft.
45 ft.
1
2
3
4" Vent Pipe
RG2PDV50H6N
RG2PDV75H6N
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90° Elbows
100 ft.
100 ft.
7 ft.
95 ft.
90
ft.
85 ft.
Printed in U.S.A.
1117-A-0215
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
●
Fax 215-641-1670 / Technical Support 800-334-3393
●
Fax 269-795-1089
●
Warranty 800-531-2111
●
Fax 269-795-1089
International: Telephone 215-641-9400
●
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
●
Fax 905-238-0105 / www.bradfordwhite.com
Concentric Vent
Kit Termination
Ambler, PA
©2015, Bradford White Corporation. All rights reserved.
2" Kit
P/N 239-44069-02
29
1
/
4
A (in.)
3" Kit
P/N 239-44069-01
36
1
/
4
A (in.)
INTAKE/
COMBUSTION
AIR
RAIN
CAP
VENT
EXHAUST
A