Spec Sheet
©2022, Bradford White Corporation, USA. All rights reserved.
Sales: 800-523-2931
n
Fax 215-641-1612
24/7 Technical Support: 800-334-3393
n
Email techserv
@
bradfordwhite.com
Products made by Bradford White are manufactured in the United States using the finest raw materials and components from around the world.
NATURAL GAS AND LIQUID PROPANE GAS
Manufactured Home Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
76% Recovery Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
B
Jacket
Dia.
in.
RG2DVMH30T6X
RG2DVMH40T6X
119
139
18
20
3
/4
3
/4
M
Water
Conn.
NPT
in.
Model
Number
Approx.
Shipping
Weight
kg.
B
Jacket
Dia.
mm.
RG2DVMH30T6X
RG2DVMH40T6X
54
63
457
508
C
Vent
Size
in.
3
3
C
Vent
Size
mm.
76
76
E
Floor to
Gas
Conn.
in.
13
3
/8
13
3
/8
E
Floor to
Gas
Conn.
mm.
340
340
1448
1451
F
Floor to
Top of
Heater
in.
F
Floor to
Top of
Heater
mm.
57
57
1
/8
570
570
G
Floor to
Cold Water
Conn.
in.
G
Floor to
Cold Water
Conn.
mm.
22
7
/16
22
7
/16
1465
1497
J
Floor to
Hot Water
Conn.
in.
J
Floor to
Hot Water
Conn.
mm.
57
11
/16
58
15
/16
549
600
H
Depth
in.
H
Depth
mm.
21
5
/8
23
5
/8
D
Floor to
T&P
Conn.
in.
50
5
/16
50
5
/16
D
Floor to
T&P
Conn.
mm.
1278
1278
19
19
M
Water
Conn.
NPT
mm.
1
/2
1
/2
S
Gas
Conn.
Size
in.
13
13
S
Gas
Conn.
Size
mm.
Model
Number
Nominal
Gal.
Capacity
Recovery at
90°F Rise*
RG2DVMH30T6X
RG2DVMH40T6X
30
40
27
33
BTU/Hr.
Input
U.S.
Gal.
Imp.
Gal.
30,000
30,000
U.S.
GPH
32
32
Imp.
GPH
27
27
LP
U.S.
GPH
32
32
LP
Imp.
GPH
27
27
LP
BTU/Hr.
Input
30,000
30,000
First
Hour
Rating
(Gal.)
56
51
DOE
Rated
Storage
Volume
(Gal.)
29
38
Uniform
Energy
Factor
0.60
0.58
Model
Number
Nominal
Liter
Capacity
Recovery at
50°C Rise*
RG2DVMH30T6X
RG2DVMH40T6X
114
151
kW
Input
8.8
8.8
LP
kW
Input
8.8
8.8
First
Hour
Rating
(Liters)
212
193
DOE
Rated
Storage
Volume
(Liters)
110
144
Uniform
Energy
Factor
0.60
0.58
Liters/
Hour
121
121
LP
Liters/
Hour
121
121
Residential Manufactured Home Direct Vent Gas Water Heater
To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.
* Based on manufacturer’s rated recovery efficiency.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Printed in U.S.A.1107-G-0322
This water heater is of the closed combustion type (direct venting) for mobile home
applications only, where all combustion air is supplied from the outdoors through the air intake
and all combusted gas products are vented directly to the outside by means of the roof jack.
No draft diverter (vent hood) is required for this water heater. The UL
®
listing of this water
heater includes the field installation of the following components: roof jack, roof jack clamp,
air intake, air intake seal, and heater tie down materials. These components for field installation
are shipped with the heater in a separate box and must be installed according to instructions.
No other components are approved for use with the water heater. The water heater must be
installed in accordance with The Federal Mobile Home Construction and Safety Standard or in
the absence of such standard, The Standard for Mobile Homes (ANSI/NFPA No. 601B-1977)
General:
Meets NAECA Requirements.
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" NPT
(19mm), all gas connections are 1⁄2" (13mm). All models design-certified by UL
®
to UL
®
307-B code and peak performance rated. Designed in accordance
with the H.U.D. Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280.707 (d)(2) for energy efficiency.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
Optional Roof Jack Kits
Part Number
12
"
18
"
/ 32
"
32
"
/ 60
"
48
"
/ 90
"
239-37022-01
239-37022-02
239-37022-03
239-37022-04
A
15"
33
1
/2"
32
1
/2"-62
1
/2"
50"-98
1
/2"
B
Through The Roof
Clearance
16"-33"
33
1
/2"-66"
37
1
/2"-74"
54
1
/2"-109
1
/2"
(Includes: roof jack, hardware, air intake, instructions).
B
22.5° Max.
A
11
5
/8"
Square
6
1
/2"
7"
4"
102
178
295
165
127
76
5"
3"
9"
2
29
(mm)
B
H
C
J
F
E
S
G
D
M
B
H
C
J
F
E
S
G
D
M