User Guide

SERVICE PROCEDURE RG-VI
Gas Control Testing, Disassembly &
Replacement (Honeywell)
Honeywell Gas Control Testing, Disassembly, and Replacement
The gas control is made up of (5) major components; the control cover, the piezo igniter, the valve body, the
temperature sensor, and the back plate. The gas control is designed so that any of these components may be
replaced without replacing the entire gas control.
LINE PRESSURE
The Gas Control is designed for a maximum line pressure of 14.0" w.c. and a minimum line pressure of 1.0"
w.c. over the water heater’s rated manifold pressure (check rating plate). Line pressure must be checked with
the main burner on and off to assure proper readings.
Gas Control
Cover
Piezo Igniter
Valve Body Backplate
Temperature
Sensor
Insertion Stick
Valve Body
Screw
Gas Control
Cover Screw