User Guide
COMBINATION THERMOSTAT/GAS VALVE REPLACEMENT
Step 1. Rotate knob of the gas valve to the “OFF” position.
Step 2. Turn off gas supply to water heater.
Step 3. Disconnect gas supply line from gas valve.
Step 4. Turn off water supply and drain water heater completely.
Step 5. Remove outer jacket burner access door.
Step 6. Right side inner door removal.
a) Disconnect resettable thermal switch wire leads (leading from gas valve)
and remove wire tie from feedline.
b) Remove (2) hex drive screws from right side inner door.
c) Remove (2) hex drive screws from flange section of inner door.
d) Remove right side inner door and set aside.
Be careful not to damage gasket material on inner door.
Resettable Thermal Switch
Wire Connection
Hex Drive Screws shown on
Right Side Inner Door
Hex Drive Screws at
Flange section of Inner Door
Remove
Wire Tie
For White Rodgers Control,
depress knob slightly and rotate
clockwise to the “OFF” position.
SERVICE PROCEDURE RG-V
Gas Valve Testing and Replacement
(White Rodgers)
17
17