SERVICE PROCEDURE RG-VI
Gas Control Testing, Disassembly, &
R
eplacement
(Resideo ONLY)
Valve body
pins
CAUTION
Use caution to not bend or damage
valve body pins when removing or
installing the gas control cover.
ICON System COVER REMOVAL
Step 1. Rotate the knob of the gas control to the “OFF” position.
Step 2. Turn off gas supply to the water heater.
Step 3. Disconnect the gas supply line from the gas control.
Step 4. Disconnect the piezo igniter wire.
Step 5. Remove the gas control cover screw using flat-head
screwdriver.
Rotate knob counter-clockwise to
the “OFF” position
Step 6. Depress both tabs on the top of the gas control cover and pull straight out to remove.
Gas control
cover screw
NOTE: The following procedure applies
to the ICON System gas control ONLY.
26