Product Overview
The AeroTherm
™
Series Heat Pump water heater
offers advanced technology and low cost operation.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Model
Number
Approx.
Shipping
Weight
lbs.
B
Jacket
Dia.
in.
C
Floor to
Water
Conn.
in.
A
Floor to
Heater
Top
in.
U.S.
Gal.
Capacity Recovery
90°F Rise
RE2H50R10
RE2H50R10B
RE2H80R10B
50
50
80
Imp.
Gal.
42
42
67
U.S.
GPH*
21
21
21
Imp.
GPH*
18
18
18
Energy
Factor
(EF)
2.4
3.1
3.1
First
Hour Rating
(FHR)
65
67
92
195
195
235
59
1
/8
59
1
/8
71
1
/8
60
3
/4
60
3
/4
73
1
/2
21
3
/4
21
3
/4
25
38
3
/4
38
3
/4
50
3
/8
F
Floor to
T&P
Conn.
in.
D
Distance
Between
Water
Conn.
in.
8
8
8
E
Floor to
Condensate
Conn.
in.
46
3
/4
46
3
/4
58
3
/4
*Energy Factor and First Hour Rating are based on latest AHRI Directory listings.
QUIET OPERATION
Operating Sound Level 55 DBA Average
POWER / RATINGS
Electrical Circuit Required 208V/240V 60 Hz Dedicated 30 Amp Min.
Electrical Consumption - Lower Element 4,000 Watts (2.4 EF = 4,500 Watts)
Electrical Consumption - Upper Element 4,500 Watts
Electrical Consumption Heat Pump 4,500 Watts Maximum Heating;
550 Watts Minimum Heating
Energy Factor (hybrid mode) Up to 3.1
First Hour Rating (FHR) Up to 92 gallons
Operating Air Temperature Range Heat Pump 45° F to 120° F (Unit operates in
Standard/Electric Mode outside of this range)
Operating Water Pressure 150 PSI Maximum Working Pressure
(30-80 PSI recommended)
A
C
E
F
D
B
Specs at a Glance
ATHRMB-0115
Dimensions and specifications subject to change without notice in
accordance with our policy of continuous product improvement.
NAECA
Compliant
2015