Product Overview
Lowboy Energy Saver Models C.E.C. Listed
Model
Number
Capacity
A
Floor to
Heater
Top
in.
Approx.
Shipping
Weight
lbs.
D
Floor to
T&P
Conn.
in.
B
Jacket
Dia.
in.
Gal.
U.S.
GPH*
Imp.
Recovery
90°F Rise
Gal.
Imp.
GPH*
U.S.
Model
Number
Capacity
Liters
A
Floor to
Heater
Top
mm.
Approx.
Shipping
Weight
kg.
D
Floor to
T&P
Conn.
mm.
B
Jacket
Dia.
mm.
Hour
Liters/
Recovery
50°C Rise
C
Floor to
Water
Conn.
in.
C
Floor to
Water
Conn.
mm.
RE120L6†
RE230L6**
RE240L6**
RE250L6**
RE120L6†
RE230L6**
RE240L6**
RE250L6**
24
7
/8
29
7
/8
32
5
/8
32
5
/8
632
759
829
829
25
5
/8
30
3
/4
33
1
/2
33
1
/2
651
781
851
851
19
1
/8
30
5
/8
33
5
/8
33
5
/8
486
778
854
854
18
22
24
26
457
559
610
660
65
129
153
183
29
59
69
83
19
28
38
47
1st Hour
Rating
(Gal.)
—
45
55
67
Energy
Factor
—
0.95
0.95
0.95
1st Hour
Rating
(Liters)
—
170
208
254
Energy
Factor
—
0.95
0.95
0.95
16
23
32
39
21
21
21
21
18
18
18
18
72
106
144
178
80
80
80
80
Residential Electric Water Heater
Printed in U.S.A.
1203-A-0315
©2015, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
●
Fax 215-641-1670 / Technical Support 800-334-3393
●
Fax 269-795-1089
●
Warranty 800-531-2111
●
Fax 269-795-1089
International: Telephone 215-641-9400
●
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
●
Fax 905-238-0105 / www.bradfordwhite.com
General:
All models ETL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase)
240V with two 4500W elements, unless otherwise specified.
All water and electrical connections are 3/4" NPT (19mm).
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.)
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Recovery
GPH Temperature Rise °F
Wattage
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
60
10
14
17
21
24
28
31
34
38
41
80
8
10
13
15
18
21
23
26
29
31
90
7
9
11
14
16
18
21
23
25
28
100
6
8
10
12
14
16
19
21
23
25
120
5
7
9
10
12
14
15
17
19
21
▲
▲(GPH based on Non-Simultaneous
operation, when Simultaneous
operation the GPH will approximately
double.)
**Models include supplied insulation blanket (2" thick).
Dimensions in charts above do not include blanket
thickness.
For 10 year models, change suffix "6" to "10".
* Based on 4500W/4500W, Non-Simultaneous
operation.
All models feature optional top T&P location and
must be specified when ordering.
† Exempt from ASHRAE 90.1b (current standard).
Energy Factor and First Hour Rating is based on the
latest AHRI directory listings.
Voltage
Wattage
Limitations for
Simultaneous
Operation
1500W / 1500W
2000W / 2000W
2500W / 2500W
3000W / 3000W
3500W / 3500W
4000W / 4000W
4500W / 4500W
5000W / 5000W
5500W / 5500W
6000W / 6000W
yes
no
no
no
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
no
no
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
240V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
480V
Voltage
Wattage
Limitations for
Non-Simultaneous
Operation
1500W / 1500W
2000W / 2000W
2500W / 2500W
3000W / 3000W
3500W / 3500W
4000W / 4000W
4500W / 4500W
5000W / 5000W
5500W / 5500W
6000W / 6000W
yes
yes
yes
yes
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
240V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
480V
B
C
A
D