Product Overview

Utility Models
C.E.C. Listed
Model
Number
Approx.
Shipping
Weight
lbs.
E
Floor to
Cold Water
Conn.
in.
B
Jacket
Dia.
in.
A
Floor to
Heater
Top
in.
U.S.
Gal.
Capacity Recovery
90°F Rise
RE16U6†
RE110U6
RE112U6
RE112T6†
RE115U6
RE120U6
6
10
12
12
15
19
Imp.
Gal.
5
8
10
10
13
16
U.S.*
GPH
7
7
7
7
7
7
Imp.*
GPH
6
6
6
6
6
6
35
44
53
48
58
65
16
1
/
2
17
1
/
2
16
7
/
8
27
3
/
4
20
1
/
4
24
3
/
4
C
Floor to
Hot Water
Conn.
in.
10
1
/
8
15
10
1
/
4
21
1
/
8
17
3
/
4
18
1
/
4
14
16
18
14
18
18
3
1
/
8
5
11
/
16
3
3
6
1
/
8
3
10
1
/
8
14
10
1
/
4
21
1
/
8
16
3
/
4
18
1
/
4
D
Floor to
T&P
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
E
Floor to
Cold Water
Conn.
mm.
B
Jacket
Dia.
mm.
A
Floor to
Heater
Top
mm.
Liters
Capacity Recovery
50°C Rise
RE16U6†
RE110U6
RE112U6
RE112T6†
RE115U6
RE120U6
23
38
45
45
57
72
Liters/*
Hour
26
26
26
26
26
26
16
20
24
22
26
29
444
246
439
730
257
260
419
445
429
705
514
629
C
Floor to
Hot Water
Conn.
mm.
257
381
260
537
451
464
356
404
457
356
457
457
79
144
76
76
156
76
F
Floor to
Anode
Rod
in.
16
1
/
2
9
11
/
16
16
1
/
2
27
3
/
4
10
1
/
8
10
1
/
4
F
Floor to
Anode
Rod
mm.
G
Floor to
Electrical
Access
in.
16
1
/
2
12
16
7
/
8
27
3
/
4
12
11
/
16
24
3
/
4
G
Floor to
Electrical
Access
mm.
419
305
429
705
322
628
257
355
260
537
425
464
D
Floor to
T&P
Conn.
mm.
Residential Electric Water Heater
General:
All models are exempt from NAECA requirements and ASHRAE Standard 90.1b.
All models ETL listed. These heaters are wired Single Phase, 120V with one 1500W element, unless otherwise specified.
All water and electrical connections are 3/4" (19mm) NPT.
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa).
Applicable models CSA-verified for energy performance in accordance with C191.1-M90.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
†Maximum wattage at any voltage is 3000W.
For 10 year models, change suffix "6" to "10".
Single element only.
*Based on 1500W operation.
Recovery
GPH Temperature Rise °F
Wattage
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
60
10
14
17
21
24
28
31
34
38
41
80
8
10
13
15
18
21
23
26
29
31
90
7
9
11
14
16
18
21
23
25
28
100
6
8
10
12
14
16
19
21
23
25
120
5
7
9
10
12
14
15
17
19
21
B
C
D
F
E
G
A
10 & 15 Gallon Models
B
F
F
C
E
D
G
A
4"
ALTERNATE
COLD INLET
(PLUGGED)
6 &12 GAL.
ONLY
PLUG TYPE
ANODE
6 &12
GAL. ONLY
ALTERNATE HOT
OUTLET (PLUGGED)
6 &12 GAL. ONLY
8"
6, 12, & 20 Gallon Models
Printed in U.S.A.
1205-A-0715
©2015, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
Fax 215-641-1670 / Technical Support 800-334-3393
Fax 269-795-1089
Warranty 800-531-2111
Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
Fax 905-238-0105 / www.bradfordwhite.com
Voltage
Wattage
Limitations
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
yes
yes
yes
yes
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
240V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
480V