Product Overview

NATURAL GAS AND LIQUID PROPANE GAS
PDX1 Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Exhaust
Outlet
in.
K
Depth
in.
B
Jacket
Dia.
in.
Capacity Recovery at
90°F Rise*
PDX1-40S6FBN
PDX1-50S6FBN
U.S.
Gal.
40
50
Imp.
Gal.
33
42
Nat.
BTU/Hr.
Input
40,000
40,000
LP
BTU/Hr.
Input
38,000
38,000
Nat.
U.S.
GPH
43
43
Nat.
Imp.
GPH
36
36
LP
U.S.
GPH
41
41
LP
Imp.
GPH
34
34
58
3
/
4
59
5
/
8
30
1
/
2
32
3
/
8
146
171
20
22
50
1
/
8
51
J
Floor
to
Water
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Exhaust
Outlet
mm.
K
Depth
mm.
B
Jacket
Dia.
mm.
Capacity Recovery at
50°C Rise*
PDX1-40S6FBN
PDX1-50S6FBN
Liters
151
190
Nat.
kW
Input
11.7
11.7
LP
kW
Input
11.0
11.0
LP
Liters/
Hour
155
155
Nat.
Liters/
Hour
163
163
1473
1499
762
813
66
78
508
559
C
Vent
Size
in.
2
2
C
Vent
Size
mm.
50
50
E
Floor
to
Gas
Conn.
in.
14
14
E
Floor
to
Gas
Conn.
mm.
346
346
F
Floor
to Top
of Heater
in.
48
3
/
4
49
5
/
8
F
Floor
to Top
of Heater
mm.
1219
1245
H
Floor to
Air
Intake
in.
55
3
/
8
56
3
/
8
H
Floor to
Air
Intake
mm.
1397
1422
D
Floor to
T&P
Conn.
in.
42
3
/
4
43
1
/
8
D
Floor to
T&P
Conn.
mm.
1067
1092
1270
1295
J
Floor
to
Water
Conn.
mm.
Residential Power Direct Vent Gas Water Heater
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm)
on 8" (203mm) centers. All gas connections are 1/2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX".
For 10 year model, change suffix “6” to “10”.
*Based on manufacturers rated recovery efficiency.
110 V.A.C Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes.
A
E
CC
Durable Cast Aluminum
Air Intake Boot
C
D
J
HF
Subtract 5ft. for each additional
90º elbow.
Consult I&O Manual when
using four or more elbows.
2" Vent Pipe
PDX1-40S
PDX1 50S
35
ft.
35
ft.
7 ft.
30 ft.
25
ft.
20 ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number 1
of 2
90° Elbows† 3
3" Vent Pipe
PDX1-40S
PDX1 50S
85 ft.
85 ft.
7 ft.
80 ft.
75 ft.
70 ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number 1
of 2
90° Elbows† 3
Printed in U.S.A.
116-B-1212-A
©2012, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
Fax 215-641-1670 / Technical Support 800-334-3393
Fax 269-795-1089
Warranty 800-531-2111
Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
Fax 905-238-0105 / www.bradfordwhite.com
INTAKE/
COMBUSTION
AIR
RAIN CAP
VENT
EXHAUST
29
1
/
4
"
2" Concentric Vent Kit Termination
P/N 239-44069-02
K