Spec Sheet

PowerCor
®
Indirect-Fired Models
Imp. U.S.
Gal. Gal.
Model Cap. Cap. Liters in. mm. in. mm. in. mm. in. mm. Lbs. Kg.
M2-P-40R10 33 40 151 20 508 46
3
4 1187 48 1219 46
3
4 1187 112 51
M2-P-50R10 42 50 189 22 559 46
1
4 1175 47
1
4 1200 46
1
4 1175 139 63
M2-P-65R10 54 65 246 22 559 58
3
4 1492 60 1524 58
3
4 1492 165 75
M2-P-80R10 67 80 303 24 610 58
3
4 1492 59
1
2 1511 58
3
4 1492 192 87
General
All models UL and C-UL listed. All units are certified at 300 PSI (2068 kPa) test pressure and
150 PSI working pressure (1034 kPa). All potable water and heat exchanger connections are
3
4" (19mm) NPT on 8" (203mm) centers.
Dimensions and specifications subject to change without notice in accordance with our
policy of continuous product improvement.
6-Year Limited Warranty on
Component Parts
BRADFORD WHITE CORPORATION has
a 6-year warranty on replaceable parts–
thermostat, dip tube, drain valve. These
quality components are manufactured
for us by industry leaders and will be
replaced in the event of failure during the
parts warranty period (exclusive of
shipping and re-installation cost.)§
10 Year Limited Tank
and Heat Exchanger Warranties
BRADFORD WHITE CORPORATION
LIMITED WARRANTY: Protects your
invest ment in a quality glass-lined water
heater and double wall heat exchanger.
If the tank or heat exchanger leaks for
reasons of faulty materials, workman -
ship, or corrosion within the warranty
period, the entire unit will be replaced
with a comparable unit of our manu -
facture (exclu sive of shipping and
re-installation cost.)§
§ Some states do not allow limitations on warranties. For products installed in USA,
Canada and Puerto Rico. See complete copy of the warranty included with the heater.
PRODUCTS ONLY FOR PROFESSIONALS
Sales/�800-523-2931
Fax/215-641-1670
Technical Support/�800-334-3393
Fax/269-795-1089
W�arranty/�800-531-2111
Fax/269-795-1089
International:
T�elephone/�215-641-9400
Telefax/215-641-9750
Ambler�, P�A�
888-538-7833
Fax on Demand:
bradfordwhite.comwww.
For U.S. and Canada field service,�
contact your professional installer or �
local Bradford White sales representative.�
Sales/Technical Support�
866-690-0961
905-238-0100
Fax/905-238-0105
Mississauga, ON�
www.bradfordwhitecanada.com
Residential Energy Saver PowerCor
®
Indirect-Fired Water Heater
Energy Saver Models
These water heaters meet or exceed the insulating standards established under
ASHRAE Standard 90.1b (current standard).
A
B
C
D
Note: Minimum Boiler Output: 70,000 BTU/H (20.5 KW/H) for M2P (40, 50) R10
Minimum Boiler Output: 84,000 BTU/H (24.6 KW/H) for M2P (65, 80) R10
Boiler Supply Temperature: 180°F (82°C) Maximum
90°F (50°C) Rise from 50° to 140°F (10° to 60°C).
Numbers subject to change.
M2-P-40R10 M2-P-50R10 M2-P-65R10 M2-P-80R10
Rec. GPH @ 90°F Rise
75 77 90 94
Rec. LPH @ 50°C Rise
284 291 341 356
1st Hour Rating @ 140°F 104 115 139 150
1st Hour Rating @ 60°C 394 435 526 568
1st Hour Rating @ 115°F 162 180 217 234
1st Hour Rating @ 46°C 613 681 821 886
A
Jacket
Diameter
B
Height
Floor to
Heater Top
C
Floor to
Water Conn.
D
Height Floor to
T&P Conn.
Approx.
Shipping
Weight
PowerCor,
®
Vitraglas,
®
Hydrojet
®
and UltraCoil
®
are registered trademarks of Bradford White
®
Corporation.
©2004, Bradford White Corporation. All rights reserved.
550-B-0904-A Printed in U.S.A.
HEAT EXCHANGER COIL
Dielectric Waterway Fitting
Cross Linked
Polyethylene
(PEX)
Outer Wall
Monofilament
Leak Path
Metallic
Inner Wall
Hot Water Outlet
Outlet Heat
Exchanger Coil
Heat Exchanger
Coil Inlet
Cold Portable
Water Inlet
T&P Valve
Connection