Installation / Operation Instruction Manual

5
Locating The Water Heater continued-
NOTE: Before proceeding with the installation, close the main water supply
valve, open a water faucet to relieve the house pressure, and then close the
faucet. If replacing an existing water heating appliance be sure to turn off all
electrical current, heating fluid and/or gas supply to the existing appliance.
A combination sacrificial anode/hot water outlet nipple has been installed to
extend tank life. The removal of this anode, for any reason other than
inspection, will nullify the warranty. In areas where water is unusually reactive,
an odor may occur at the hot water faucet due to a reaction between the
sacrificial anode and the impurities in the water. If this should happen, an
alternative anode may be purchased from the manufacturer or the plumbing
professional responsible for this installation. This will minimize the odor while
protecting the tank. Additionally, the indirect water heater should be flushed
with appropriate dissolvers to eliminate any bacteria. The sacrificial anode
should be inspected periodically and replaced when necessary to prolong tank
life. Please contact the manufacturer listed on the rating plate for more
information regarding the replacement for the anode.
Water Connections
Potable Water
NOTE: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE
MAIN WATER SUPPLY VALVE.
After shutting the main water supply valve, open a faucet to relieve the water
line pressure to prevent any water from leaking out of the pipes while making
the water connections to the water heater. After the pressure has been
relieved, close the faucet. The COLD water inlet and HOT water outlet are
identified on top of the water heater. The fittings at the cold water inlet and hot
water outlet are dielectric waterway fittings with 3/4” NPT tapered male threads.
Make the proper plumbing connections between the water heater and the
plumbing system in the house. Install a shut-off valve in the cold water supply
line.
CAUTION
If sweat fittings are to be used, DO NOT apply heat to the nipples on top
of the water heater. Sweat the tubing to the adapter before fitting the
adapter to the water connections. It is imperative that heat is not applied
to the nipples containing a plastic liner.