Installation / Operation Instruction Manual

37
Troubleshooting continued-
LEDStatus ControlStatus ProbableCause
Sixflashestwo
flashes,threesecond
pause(Softlockout)
Pressureswitchor
blowertemperature
switchopened
duringburner
operation.
Systemautoresets
after5minutes.
1.Pressureswitchtubingkinkedorblocked.
2.Ventblockageorimproperventconfiguration.
3.Ventterminationbeingaffectedbywindy
conditions.
4.Blowernotspinning
uptospeed.
5.Venttemperaturetoohigh.
6.Faultypressureswitchorblowertemp.switch.
Sixflashesthree
flashes,threesecond
pause(Softlockout)
Pilotflame
extinguished.
Systemresetsafter5
minutes.
1.Unstablepilot.
2.Pilottubeblockedorrestricted.
3.Oxidationbuilduponpilotelectrode.
4.Wiredamagetopilotassemblyorbad
connectionatgasvalve.
5.Insufficientcombustionair.
Sixflashesfour
flashes,threesecond
pause(Softlockout)
Undesiredfalsepilot
flamesensed.
Systemautoresets.
Pilotvalvestuckinopenposition.
Sevenflashes,three
secondpause
Flammablevapor
sensorfault
detected,see
warninglabel
1.Flammablevaporpresent
2.Flammablevaporsensorexposedtoexcessive
moisture
3.Flammablevaporsensorexposedtoextreme
ambienttemp
Eightflashesone
flash,threesecond
pause
Flammablevapor
sensoroutof
specification.
Possibleshort.
1.Flammablevaporsensoroutofspecification
2.Possibleshort.
Eightflashes,two
flashes,threesecond
pause
Temperaturesensor
fault
1.Damagetosensororwireincontrol’swell.
2.Control’ssensorresistanceoutofrange.
3.Replacecontrol.
Eightflashesthree
flashes,threesecond
pause
Electronicsfault
detected
1.Verifycontrolisnotwetorphysicallydamaged
2.Resetcontrolon/offswitch.
3.Replaceelectronicmoduleif83errorpersists
Eightflashesfour
flashes,threesecond
pause
Gasvalvefault
detected.
1.Verifycontrolisnotwetorphysicallydamaged.
2.Resetcontrolon/offswitch.
3.Replacegascontrolif84errorpersists