Spec Sheet

Light Duty Upright Energy Saver Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
Capacity
A
Floor to
Heater
Top
in.
Approx.
Shipping
Weight
lbs.
D
Floor to
T&P
Conn.
in.
B
Jacket
Dia.
in.
Gal.
U.S.
GPH*
Imp.
Recovery
100°F Rise
Gal.
Imp.
GPH*
U.S.
Model
Number
Capacity
Liters
A
Floor to
Heater
Top
mm.
Approx.
Shipping
Weight
kg.
D
Floor to
T&P
Conn.
mm.
B
Jacket
Dia.
mm.
Hour*
Liters/
Recovery
56°C Rise
C
Floor to
Water
Conn.
in.
C
Floor to
Water
Conn.
mm.
LD-30R3-3
LD-40S3-3
LD-50S3-3
LD-65R3-3
LD-80R3-3
LD-120R3-3
LD-30R3-3
LD-40S3-3
LD-50S3-3
LD-65R3-3
LD-80R3-3
LD-120R3-3
30
40
50
65
80
119
25
33
42
54
67
99
18
18
18
18
18
18
15
15
15
15
15
15
18
20
22
22
24
28
85
103
130
156
183
305
114
151
189
246
303
450
68
68
68
68
68
68
1191
1191
1181
1505
1505
1594
457
508
559
559
610
711
1222
1216
1207
1530
1530
1632
1199
1191
1181
1505
1505
1581
39
47
59
71
83
138
47
3
/
16
46
7
/
8
46
1
/
2
59
1
/
4
59
1
/
4
62
1
/
4
E
Floor to
Electrical
Access
in.
E
Floor to
Electrical
Access
mm.
1238
1222
1213
1537
1537
1626
48
3
/
4
48
1
/
8
47
3
/
4
60
1
/
2
60
1
/
2
64
46
7
/
8
46
7
/
8
46
1
/
2
59
1
/
4
59
1
/
4
62
3
/
4
First Hour
Rating**
Gal.
First Hour
Rating**
Liters
189
212
254
291
348
447
50
56
67
77
92
118
48
1
/
8
47
7
/
8
47
1
/
2
60
1
/
4
60
1
/
4
64
1
/
4
Commercial Electric Water Heater
General
All models ETL listed. These heaters are wired inter-locking (Non-Simultaneous, Three Phase) 240V with two 4500W elements, unless
otherwise specified.
All water and electrical connections are 3/4" NPT (19mm), 120 gallon model has 1" NPT (25mm).
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.)
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Specify wattage and voltage when ordering.
Use chart to right for maximum wattages at certain voltages
For 5 year models, change suffix "3" to "5".
*Based on 4500W/4500W, Non-Simultaneous operation.
**First Hour Rating is based on the latest AHRI Directory listings.
NSF construction not available.
Voltage
Wattage
Limitations for
Non-Simultaneous
and Simultaneous
Operation
1500W / 1500W
2000W / 2000W
2500W / 2500W
3000W / 3000W
3500W / 3500W
4000W / 4000W
4500W / 4500W
5000W / 5000W
5500W / 5500W
6000W / 6000W
yes
no
no
no
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
no
no
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
240V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
480V
Recovery
GPH Temperature Rise °F
Wattage
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
60
10
14
17
21
24
28
31
34
38
41
80
8
10
13
15
18
21
23
26
29
31
90
7
9
11
14
16
18
21
23
25
28
100
6
8
10
12
14
16
18
21
23
25
120
5
7
9
10
12
14
15
17
19
21
(GPH based on Non-Simultaneous
operation, when Simultaneous
operation the GPH will
approximately double.)
E
Printed in U.S.A.
410-B 1213
©2013, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
Fax 215-641-1670 / Technical Support 800-334-3393
Fax 269-795-1089
Warranty 800-531-2111
Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
Fax 905-238-0105 / www.bradfordwhite.com