Product Overview

NATURAL GAS AND LIQUID PROPANE GAS
eF Series
®
Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Heater
Top
in.
B
Jacket
Dia.
in.
Capacity Recovery at
90°F Rise*
EFR-1-60T1206EN
U.S.
Gal.
60
Imp.
Gal.
50
Nat.
BTU/Hr.
Input
120,000
LP
BTU/Hr.
Input
120,000
Nat.
U.S.
GPH
154
Nat.
Imp.
GPH
128
LP
U.S.
GPH
154
LP
Imp.
GPH
128 57 57028
1
/
4
G
Floor to
Exhaust
Vent
Conn.
in.
5
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Heater
Top
mm.
B
Jacket
Dia.
mm.
Capacity Recovery at
50°C Rise*
EFR-1-60T1206EN
Liters
227
Nat.
kW
Input
35.2
LP
kW
Input
35.2
LP
Liters/
Hour
581
Nat.
Liters/
Hour
581 1448 259
Thermal
Efficiency
95%
Thermal
Efficiency
95% 718
C
Vent
Size
in.
3
C
Vent
Size
mm.
76
D
Floor to
T&P
Conn.
in.
40
D
Floor to
T&P
Conn.
mm.
1016
G
Floor to
Exhaust
Vent
Conn.
mm.
127
H
Floor to
Cold
Water
Inlet
in.
13
H
Floor to
Cold
Water
Inlet
mm.
330
J
Floor to
Hot
Water
Outlet
in.
42
1
/
2
J
Floor to
Hot
Water
Outlet
mm.
1080
E
Floor to
Gas
Conn.
in.
53
1
/
2
E
Floor to
Gas
Conn.
mm.
1359
F
Floor to
Air
Intake
Conn.
in.
52
1
/
2
F
Floor to
Air
Intake
Conn.
mm.
1334
Residential Ultra High Efficiency Gas Water Heater
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 1" NPT (25mm).
All gas connections are 3/4" (19mm).
All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Air intake cannot exceed exhaust by
more than 30 ft. in any venting situation.
Subtract 5 ft. for each additional 90°
elbow.
†Consult I&O Manual when using four or
more elbows.
3" Vent Pipe
Power
Direct Vent
60 ft.
60 ft.
7 ft.
55 ft.
50
ft.
45 ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number 1
of 2
90° Elbows† 3
4" Vent Pipe
Power
Direct Vent
85 ft.
85 ft.
7 ft.
80 ft.
75
ft.
70 ft.
Power
Vent
N/A
120 ft.
7 ft.
115 ft.
110 ft.
105 ft.
2" Vent Pipe
Power
Direct Vent
30 ft.
30 ft.
7 ft.
25 ft.
20
ft.
15 ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number 1
of 2
90° Elbows† 3
Power
Vent
N/A
60 ft.
7 ft.
55 ft.
50 ft.
45 ft.
Power
Vent
N/A
170 ft.
7 ft.
165 ft.
160 ft.
155 ft.
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number 1
of 2
90° Elbows† 3
Printed in U.S.A.
123-B-0612-A
©2012, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
Fax 215-641-1670 / Technical Support 800-334-3393
Fax 269-795-1089
Warranty 800-531-2111
Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
Fax 905-238-0105 / www.bradfordwhite.com
For Propane (LP) models change suffix "EN" to "SX".
*Based on manufacturers rated recovery efficiency.
115V A.C. Required. Amp Draw Range = 1.0 - 1.8 amps.
H
D
J
F
E
G
C
C
A
B
INTAKE/
COMBUSTION
AIR
RAIN CAP
VENT
EXHAUST
46
3
/
4
"
3" Concentric Vent Terminal Kit
P/N 239-44069-01
INTAKE/
COMBUSTION
AIR
RAIN CAP
VENT
EXHAUST
33
3
/
8
"
2" Concentric Vent Kit Termination
P/N 239-44069-02