Spec Sheet

ElectriFLEX MD
Electric Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
Approx.
Shipping
Weight
lbs.
E
Floor to
Cold Water
Conn.
in.
B
Jacket
Dia.
in.
A
Floor to
Heater
Top
in.
U.S.
Gal.
Capacity Recovery
100°F Rise
E32-50S-3
E32-80R-3
E32-120R-3
50
80
119
Imp.
Gal.
42
67
99
U.S.*
GPH
74
74
74
Imp.*
GPH
62
62
62
137
190
312
46
1
/2
59
63
C
Floor to
Water
Conn.
in.
47
1
/2
60
64
22
24
28
1
/4
59
1
/8
59
3
/8
50
59
5
/8
60
3
/4
3
1
/8
3
3
4
1
/2
47
5
/8
60
1
/8
64
1
/8
D
Floor to
T&P
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
E
Floor to
Cold Water
Conn.
mm.
B
Jacket
Dia.
mm.
A
Floor to
Heater
Top
mm.
Liters
Capacity Recovery
56°C Rise
E32-50S-3
E32-80R-3
E32-120R-3
189
303
450
Liters/*
Hour
280
280
280
62
86
142
1140
1457
1568
1181
1499
1600
C
Floor to
Water
Conn.
mm.
1207
1524
1626
559
610
730
79
76
76
114
E
Floor to
Control
Box
in.
44
7
/8
57
3
/8
61
3
/8
E
Floor to
Control
Box
mm.
F
Control Box
to Back of
Heater
in.
24
5
/8
26
3
/4
30
7
/8
F
Control Box
to Back of
Heater
mm.
625
679
784
1210
1527
1629
D
Floor to
T&P
Conn.
mm.
Commercial Electric Water Heater
General
All models ETL listed.
All potable water connections are 1
1
4" NPT (25mm) on 8" (203mm) centers.
All electrical connections are 3/4" (19mm) NPT.
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa).
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Printed in U.S.A.450-B-0716-A
©2016, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
l
Fax 215-641-1670 / Technical Support 800-334-3393
l
Fax 269-795-1089
l
Warranty 800-531-2111
l
Fax 269-795-1089
International: Telephone 215-641-9400
l
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
l
Fax 905-238-0105 / www.bradfordwhite.com
All models are wired 240V, 3-phase, 18kW. Other voltages, wattages and kW are available and must be specified when ordering.
For 5 year models, change suffix “3” to “5”.
*Based on 18kW operation.
NSF Construction available.
A D
C
B
F
E
10"
3
1
/8"
Required
Total
Heater
kW
Each
Element
Wattage
Kit Part Numbers
208V
Conversion Kit T
able
240V 480V
6
9
12
13.5
15
18
2000
3000
4000
4500
5000
6000
265-43942-13
265-43942-14
265-43942-15
265-43942-16
265-43942-17
265-43942-18*
265-43942-07
265-43942-08
265-43942-09
265-43942-10
265-43942-11
265-43942-12
265-43942-01
265-43942-02
265-43942-03
265-43942-04
265-43942-05
265-43942-06
208V 240V 277V
Full Load Amperes - (Single Phase / Three Phase) and Recover
y at °F Rise
380V 415V 480V 40°F
28.8/16.7
43.2/25.0
57.7/33.3
64.9/37.5
72.1/41.6
86.5/50.0
Input kW
6
9
12
13.5
15
18
25.0/14.4
37.5/21.7
50.0/28.9
56.3/32.5
62.5/36.1
75.0/43.3
21.7
32.5
43.3
48.7
54.2
65.0
9.1
13.7
18.2
20.5
22.8
27.3
8.3
12.5
16.7
18.8
20.9
25.0
12.5/7.2
18.8/10.8
25.0/14.4
28.1/16.2
31.3/18.0
37.5/21.7
62
93
124
139
155
186
100°F
25
37
50
56
62
74
140°F
18
27
35
40
44
53
Sample Specification
Water heater shall be a Bradford White model with a rated storage capacity of not less than _______ gallons/liters, a minimum kW input of _______, and a
minimum recovery of _______ GPH/LPH at 100°F (56°C) temperature rise. It shall be designed certified either with or without a separate storage tank. The
tank shall be lined with Vitraglas
®
vitreous enamel. The tank should consist of three screw type elements with a combined maximum input of 18 kW. The
tank shall have one magnesium anode rod. The units should be design certified by ETL for field conversions with specific kits available from the factory.
The heater shall be insulated with not less than 2" (51mm) of Non-CFC foam. This water heater shall be equipped with an ASME rated T&P relief valve. The
entire installation shall be made in compliance with state and local codes and ordinances.
*265-43942-18 will require control box replacement
(included in kit). Other wattages, wiring phase and kW
are available and must be specified when ordering. 277
volt cannot be ordered as 3 phase operation.