Water Connections continued-
NOTICE
Typical steam boiler without connections available below the water line
is not recommended due to insufficient water temperature, especially
during warmer months when the space heating system is not
operational. Boiler water temperature at the bottom of a steam boiler
can be 50°F lower than the boiler’s water temperature limit setting
during such periods.
FILL BOILER SYSTEM
1. On new boiler installations, do not purge the boiler or space heating
system through the water heater. During any boiler or space heating
system flushing, cleaning, or purging, the water heater should be
isolated to avoid possible attack on the carbon steel coil by chemical
additives.
2. Purge air from boiler/water heater piping.
3. Check system for leaks. Repair as necessary.
SECTION VI
ELECTRICAL CONNECTIONS
Install electric wiring in accordance with National Electric Code or the
Canadian Electrical Code and local regulations. See the boiler’s
installation manual for wiring diagrams.
DANGER
Positively assure all electrical connections are unpowered before
attempting installation or service of electrical components or connections
of the water heater or building. Lock out all electrical boxes with padlock
once power is turned OFF.
WARNING
When installed, the water heater must be electrically grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, and /or the CSA C22.1 Electric
Code.
Failure to properly wire electrical connections to the water heater may
result in serious physical harm.
Electrical power may be from more than one source. Make sure all
power is off before attempting any electrical work.