Installation / Operation Instruction Manual
10
SECTION III
GENERAL INFORMATION
FEATURES
This water heater contains the following features:
HEAT EXCHANGER – The heat exchanger (coil) has 3/4” NPT
female fittings.
Water heaters with a double-wall heat exchanger meet the
Uniform Plumbing Code for installation in all potable water
systems. The double-wall construction provides protection in the
event that either the potable or hydronic heat exchanger barrier is
penetrated. The fluid will move along in integrated leak path within
the heat exchanger, leaving the exchanger through a weep hole
located in the fittings. If a confirmed leak occurs, contact the
plumbing professional who installed the water heater or the
manufacturer, listed on the rating plate, for additional guidance.
This indirect-fired water heater is appropriate for all potable
heating systems, even where a single-wall exchanger is not
approved by the authority having jurisdiction.
ADJUSTABLE THERMOSTAT – The temperature may be
adjusted from approximately 80°F to approximately160°F. The
thermostat is factory set at 120°F. It is recommended that lower
temperatures be used to avoid the risk of scalding. Refer to the
“Warnings” and the section on SCALDING in “Section VII –
Operating Instructions.” It is further recommended, in all cases,
that the water temperature be set for the lowest temperature that
satisfies your hot water needs. This will also provide the most
energy efficient operation of the water heater and minimizes scale
formation.
Setting the water heater temperature at 120°F will reduce the risk
of scalds. Some states require settings to specific lower
temperatures.